background image

Dealer: This manual MUST be given to the end 
user.
User: Before using this product, read this 
manual and save for future reference.

For more information regarding 

Invacare products, parts, and services, 

please visit www.invacare.com

User Manual

Invacare® Element™

Pneumatic Conserver

IOC100P

Summary of Contents for Element IOC100P

Page 1: ...nd user User Before using this product read this manual and save for future reference For more information regarding Invacare products parts and services please visit www invacare com User Manual Inva...

Page 2: ...tions or instructions contact a healthcare professional dealer or technical personnel before attempting to use this equipment otherwise injury or damage may occur ACCESSORIES WARNING Invacare products...

Page 3: ...6 SECTION 1 GENERAL GUIDELINES 7 Operating Information 7 SECTION 2 FEATURES 10 SECTION 3 INSTALLING THE CONSERVING REGULATOR 12 SECTION 4 OPERATING INSTRUCTIONS 14 SECTION 5 REMOVING THE CONSERVING R...

Page 4: ...used as part of a portable oxygen delivery system for patients that require supplemental oxygen in their home and for ambulatory use Disposal Instructions This device and its packaging contain no haz...

Page 5: ...g to the patient It supplies a pulse of oxygen atthebeginningofeachbreath Thisreducestheoxygendemand on the system and limits the drying of the airways The flow is determined by setting the flow contr...

Page 6: ...and eliminating unnecessary oxygen waste When we breathe approximately one third of the time is spent inhaling and two thirds exhaling As a result oxygen delivered by continuous flow is wasted during...

Page 7: ...icensed by the law of the state in which he she practices to use or order the use of this device This product is not intended as a life sustaining or life supporting device Only personnel instructed a...

Page 8: ...xplosive substances vapors or atmosphere ALWAYS follow ANSI and CGA standards for Medical Gas Products and Flowmeters E 7 and Oxygen Handling G 4 NO OXYGEN is delivered when the pointer is aligned wit...

Page 9: ...r lubricant such as WD 40 or 3 in 1 oil If continued difficulty is experienced contact your supplier for assistance DO NOT store cylinders near sources of heat or flame DO NOT use while sleeping witho...

Page 10: ...e back page Model IOC100P FIGURE 2 1 Model IOC100P Cylinder Post Valve T Handle Clamp This is used to attach the unit to any CGA870 post valve cylinder Oxygen Pressure Gauge Enables the user to monito...

Page 11: ...nto the holes on the CGA870 post valve CGA870 Seal Washer Metal Washer with Viton or equivalent Seal Creates the interface between the post valve and the conserver regulator Besides offering a rugged...

Page 12: ...or to use If the cylinder post valve should come in contact with such substances it should be cleaned off with a damp cloth prior to connecting it to the conserving regulator DO NOT direct flow of oxy...

Page 13: ...ins toward the holes on the cylinder neck 3 Align the two pins and gasket with the corresponding holes on the cylinder post valve FIGURE 3 1 Attaching the IOC100P to the Cylinder NOTE Cylinder post va...

Page 14: ...ng when the oxygen conserving regulator is in use This may damage the oxygen conserving regulator 1 Prior to each use inspect product for visible damage DO NOT use if any damage is found WARNING DO NO...

Page 15: ...ed 7 Position the cylinder so the oxygen cylinder valve outlet is pointing away from the user and any other person s 8 Attach a standard adult single lumen oxygen nasal cannula no longer than seven fe...

Page 16: ...n continuous flow mode is preset to 2 L min liters per minute Remember that in this mode the oxygen will be consumed at a much faster rate Return to another source before running out of oxygen Refer t...

Page 17: ...ygen supply cylinder valve and continue breathing through the nasal cannula until no further oxygen flow is detected 13 Remove the nasal cannula and turn the selector switch to the 0 OFF position 14 W...

Page 18: ...le beyond the stop Otherwise damage to the oxygen conserving regulator will occur NOTE For information on how to operate the cylinder consult your equipment provider 1 Completely close the oxygen cyli...

Page 19: ...RESSURE 200 psi to 3000 psi 13 8 bar to 206 8 bar REGULATOR Built in 25 5 psi 1 7 bar 34 bar brass high pressure with aluminum low pressure materials DIMENSIONS Weight Approximately 14 8 ounces 420 gr...

Page 20: ...minute as compared with ten 10 times per minute Refer to OXYGEN DURATION TABLE below OXYGEN DURATION TABLE SHOCK VIBRATION Not to exceed IEC 601 1 requirements Not to exceed IEC 68 2 6 IEC 68 2 34 No...

Page 21: ...lutions DO NOT immerse product in any kind of liquid All repairs MUST be done by Invacare Corporation 1 Disconnect all connections before cleaning 2 After each use clean exterior of the product with a...

Page 22: ...Oxygen conserving regulator not sensing breath 5 Oxygen cannula is blocked or kinked 1 Turnthecylindervalveto the ON position 2 Set to prescribed setting 3 Replace cylinder 4 Check position of cannul...

Page 23: ...ee telephone number identified on the back cover of this manual Upon receiving notice of an alleged defect in a product Invacare will issue a serialized return authorization It shall be the responsibi...

Page 24: ...INCIDENTAL OR CONSEQUENTIAL DAMAGE OR LIMITATION OF HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE EXCLUSION AND LIMITATION MAY NOT BE APPLICABLE THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE...