– 5020 – AA Installation and use of built-in Visio call panel 02-0154-EN  

Page 11 / 12 

CERTIFICATE OF CONFORMITY 

A)

 

Standards: 

EC standards: 

The central unit complies with the 

R&TTE Directive 1999/5/EC

: electrical safety 

standard 

EN 60950(2001)

 applied, EMC standard 

EN 301 489-3 (2002)

 applied, radio 

standard 

EN 300 330-2 (2001)

 applied  

The central unit complies with the telephone network standards 

TS-103 021

 and 

TR-

103 000

 

Cabling: 

The cables connected to the central unit must not be placed in the vicinity of other 
sources of electrical power (e.g. mains power supply). 
 

Operating warranty: 

The call panel is guaranteed for a temperature range of between 

-20°C and +70°C 

and 

for relative humidity not exceeding 70%. 
 

End of life product recycling: 

The panel and its accessories must not be disposed of with unsorted municipal 
waste but must be follow the WEEE (Waste Electrical and Electronic Equipment 
Directive) collection and recycling channel.

Summary of Contents for 02-0154-EN

Page 1: ...cted to the following real time central units 2 to 4 doors ref 03 0101 EN 1 door ref 03 0102 EN Ideal for installation near an entrance gate four opening methods are possible By using an authorised badge By typing in a specific code By calling a resident using the call panel who then opens the gate using a key on his her telephone Using a mobilekey Product description The Visio telephone intercom ...

Page 2: ...F CONNECTING AN ENTRANCE GATE WITH THE 2 TYPES OF CENTRAL UNITS 6 D SCENARIO OF CONNECTING AN ENTRANCE GATE PLUS A BUILDING 6 EQUIPMENT CONFIGURATION 7 A GENERAL POINTS 7 B CONFIGURATION WITH A RESIDENTIAL CENTRAL UNIT 03 0101 EN 7 C CONFIGURATION WITH AN INTRACODE 03 0102 EN CENTRAL UNIT 8 POST FITTING CHECK 9 D ON THE PANEL 9 E DOOR CONNECTION 9 F CALLS 9 A KEYPAD CODE 9 DIAGNOSIS IN THE EVENT O...

Page 3: ...EN V233 5020 AA Installation and use of built in Visio call panel 02 0154 EN Page 3 12 Dimensions and assembly A Dimensions of call panel ...

Page 4: ...EN V233 5020 AA Installation and use of built in Visio call panel 02 0154 EN Page 4 12 B Built in box dimensions ...

Page 5: ...tral unit supplies power to the call panel via the terminals CABLING Twisted pairs Diameter 0 8 Max distance 100 metres B For AUDIO calls only Connect the following terminals up to the central unit Terminal Detail Pair Qty Power supply 1 D D Data 1 A A Audio 1 03 0102 EN 17 0101 EN D D D D A A Power supply 12 24 V 2 to 4 A Not supplied D D A A 17 0101 EN 03 0101 EN D D A A Twisted pair recommended...

Page 6: ...of connecting an entrance gate plus a building It is mandatory to use an 03 0101 EN central unit with in this example an extension board Scenario Audio calls from the entrance gate Audio calls can be made from the building entrance 4 2 6 6 6 Add an extension board doors 3 and 4 6 6 In this example door 4 remains available 41 49 and CRT Connections in black refer to and D D and A A Extension board ...

Page 7: ...y then the Enter password menu appears o Type the serial number of the 03 0101 EN central unit 000xxxxx o Validate with the V key You are in menu settings mode Menu options in settings mode Setting the clock Date 28 01 13 Day Monday Numeric keys for date entry Key to select day Time 09 15 Type winter Numeric keys for time entry Key to select summer winter season Accept remote time YES Key to selec...

Page 8: ...racode 03 0102 EN central unit Presets selection is performed by switches actuation on the Central unit card on the right hand side of the battery Switch 1 to 3 NA Switch 4 and 5 combination graduate the opening time Sw4 on 5 sec On 10 sec Off 20 sec Sw5 on off on Switch 6 select door open PB type Sw6 on NO off NC ...

Page 9: ...e in the central unit guide F Calls To call a resident you have to select his flat s number on the keyboard and then press call pb to validate your selection or cancel pb in any case if you want to reset or make a new selection Trade pb is dedicated to offer a free acces for trades during a time range This function has to be configured on the website in Panel parameters Call button time range Chec...

Page 10: ...t Keys backlit but not display or the reverse Contact our technical support department The LCD screen does not turn on Incorrect cabling on the and or terminals Check cabling between the central unit and the call panel When swiping a badge the green LED on the reader lights up but the door does not open Relay on the central unit not working Cable to the door Check if relay sticks Check cabling bet...

Page 11: ... telephone network standards TS 103 021 and TR 103 000 Cabling The cables connected to the central unit must not be placed in the vicinity of other sources of electrical power e g mains power supply Operating warranty The call panel is guaranteed for a temperature range of between 20 C and 70 C and for relative humidity not exceeding 70 End of life product recycling The panel and its accessories m...

Page 12: ...EN V233 5020 AA Installation and use of built in Visio call panel 02 0154 EN Page 12 12 B Certificate ...

Reviews: