Technical specifications
Kendrion INTORQ | BA 14.0223 | 04/2022
15
4
Technical specifications
4.1
Possible applications of the Kendrion INTORQ spring-applied brake
¾
Degree of protection:
– The brake is designed for operation under the operating conditions that apply to IP54 protection.
Because of the numerous possibilities of using the brake, it is still necessary to check the function-
ality of all mechanical components under the corresponding operating conditions.
¾
Ambient temperature:
– -20 °C to +50 °C (Standard)
4.2
Characteristics
Size
Brake torque
Max. permissible
switching energy
Air gap
Moment of in-
ertia of rotor
Weight of
brake
Rated value at
Δn=100 rpm
Rated value of
the H-version
M
K
M
K
Q
E
S
LN
1)
S
Lmax
J
Rotor
m
[Nm]
[Nm]
[J]
[mm]
[mm]
[kg cm
2
]
[kg]
06
2.5
2
3000
0.2
-0.1
0.5
0.130
0.86
3
2.5
0.4
5
4
0.3
08
5
4
7500
0.2
-0.1
0.5
0.450
1.34
7
5
0.4
10
8
0.3
10
10
8
12000
0.25
-0.1
0.6
2.0
2.58
13
10
0.5
20
16
0.35
12
20
16
24000
0.3
-0.1
0.65
4.5
3.77
27
21
0.55
40
32
0.4
Tab. 1:
General data
1)
The default (as delivered) air gap results from the sum tolerances of the individual components. These operating
times are specified for usage of Kendrion INTORQ bridge/half-wave rectifiers and coils with a connection voltage of
205 V DC at s
LN
and 0.7*I
N
.