Commissioning and operation
INTORQ | BA 14.0200 | 02/2016
37
13. Screw the bridges back onto the motor terminals. Remove additional PE conductor, if necessary.
6.4
Commissioning
1. Switch on the drive system.
2. Carry out several test brake checks.
6.5
During operation
❚
Checks must be carried out regularly. Pay special attention to:
-
unusual noises or temperatures
-
loose attachment elements
-
the condition of the electrical cables
-
The armature plate must be tightened and the rotor must move without residual torque.
❚
Measure the DC voltage at the brake.
-
The release voltage is applied for about 1.3 sec. The system is then reduced to the holding voltage
(refer to the nameplate).
❚
If faults or malfunctions occur, refer to the error search table (
46). If the fault cannot be fixed or elim-
inated, please contact your customer service.
Contact type
Connection
Brake released
Proximity switch:
Signal is present
N/O contact
black / blue / brown +24 V yes
yes
no
yes
Wear limit has been
reached
no
Tab. 15:
Switching status of the proximity switch for checking the wear
DANGER
There is a risk of injury by electrical shock!
❚
Live connections must not be touched.