background image

299

A

(299IO)  SPA (JET + BUBBLE)  ENGLISH  7.5” X 10.3”  PANTONE 295U  05/30/2018

English

OWNER’S MANUAL

PureSpa™ 

SJB-HS-20-1C / SJB-HS-22

SJB-HS-30-1C / SJB-HS-33

IMPORTANT 

SAFETY RULES

Please read, understand, and follow 

all instructions carefully before 

installing and using this product.

Keep for future reference.

299-*A*-R0-1905

Do not forget to try these other fi ne Intex products: pools, pool 
accessories, in-home toys, airbeds and boats available at fi ne 
retailers or visit our website.

Due to a policy of continuous product improvement, Intex reserves 
the right to change specifi cations and appearance, which may 
result in updates to the instruction manual without notice.

For illustrative purposes only. 

©2018 Intex Marketing Ltd. - Intex Development Co. Ltd. - Intex Recreation Corp.
All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle 
Rechte vorbehalten. Printed in China/Imprimé en Chine/Impreso en China/
Gedruckt in China.

®™ Trademarks used in some countries of the world under license from/®™ Marques utilisées dans certains pays sous 
licence de/Marcas registradas utilizadas en algunos países del mundo bajo licencia de/Warenzeichen verwendet in einigen 
Ländern der Welt in Lizenz von/

Intex Marketing Ltd. to/à/a/an Intex Development Co. Ltd., G.P.O Box 28829, Hong 

Kong & Intex Recreation Corp., P.O. Box 1440, Long Beach, CA 90801

 • Distributed in the European Union by/Distribué 

dans l’Union Européenne par/Distribuido en la unión Europea por/Vertrieb in der Europäischen Union durch/

Intex Trading 

B.V., Venneveld 9, 4705 RR Roosendaal – The Netherlands
www.intexcorp.com

Summary of Contents for PureSpa SJB-HS-20-1C

Page 1: ...oses only 2018 Intex Marketing Ltd Intex Development Co Ltd Intex Recreation Corp All rights reserved Tous droits réservés Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprimé en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilisées dans certains pays sous licence de Marcas registradas utilizadas en al...

Page 2: ...Warning 3 6 Parts 7 8 Product Information Specifications 9 Set up 9 13 Salt Level Information 14 Operation 15 16 LED Code Chart 17 Minimize Heat Loss and Energy Consumption Advice 17 Maintenance and Chemicals 18 24 Storage 24 Troubleshooting 25 27 Filter pump motor disassembly 28 Warranty 29 TABLE OF CONTENTS ...

Page 3: ... and 40 C 104 F are considered safe for a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes It is recommended to seek medical advice before use b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit spa water temperature and ...

Page 4: ... when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37 C 98 6 F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsiness and fainting The effects of hyperthermia include failure to perceive heat failure to recognize the need to exit spa or hot tub unawareness of impending hazar...

Page 5: ... Do not add bath oil or bath salt to the spa water The spa must be setup on a level flat and smooth surface that is capable of supporting the maximum load of the filled spa with four adult occupants weight 2500 lbs 1136 kg six adults 3500 lbs 1592 kg Provide adequate drainage system around the spa to deal with overflow water and splashes Use accessories exclusively provided by the spa manufacturer...

Page 6: ... the spa if the RCD does not function properly Disconnect the power cord until the fault has been identified and corrected Contact a qualified electrician to correct the fault Do not bypass the RCD There are no serviceable parts inside the RCD Opening the RCD will void the warranty Barriers covers alarms or similar safety devices are helpful aids but they are not substitutes for continuous and com...

Page 7: ...ge 7 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale 10 5 8 21 1 6 3 4 12 13 16 11 14 26 22 15 23 30 29 28 20 31 32 33 2 27 9 24 35 34 7 18 17 19 25 ...

Page 8: ...5 11 SPA DRAIN VALVE ADAPTOR 1 11718 11718 12 FILTER CARTRIDGE HOUSING 1 11798 11798 13 FILTER CARTRIDGE 3 11692 11692 14 FILTER CARTRIDGE HOUSING LID 1 11797 11797 15 INLET PLUG 1 11739 11739 16 SPA TUB 1 12090 12116 17 SPA COVER 1 11951 12117 18 SPA COVER INFLATABLE BLADDER PRE INSTALLED IN SPA COVER 1 11884 12114 19 GROUND CLOTH 1 11933 12110 20 ELECTROLYTIC CELL NUT WRENCH 1 11854 11854 21 TES...

Page 9: ...p surface Do not install the spa on carpet or other materials that will be damaged by moisture condensation Do not install the spa indoors on a second floor above finished living space due to the possibility of water and humidity damage Humidity is a natural side effect of indoor spa installation The room shall be properly ventilated to allow moisture to escape Install a ventilating system to prev...

Page 10: ...the ground cloth with the bubbles facing down over the cleared area where you intend to setup your spa 2 Screw the control panel bolts 4 with the provided bolt wrench 6 to secure the control panel see drawing 2 3 Plug the spa control unit into an electrical outlet Inflation Inflate the Spa Tub Wall 1 Take out the ground cloth 19 and spread it over the cleared area Then spread out the spa liner ove...

Page 11: ...the bladder 4 Press the button to turn on the control unit panel buttons first Press the button to inflate the spa tub wall for 8 to 10 minutes until it is firm to the touch but not hard see drawing 5 IMPORTANT Do not over inflate or use high pressure air compressor to inflate 5 Press the button again to turn it off 6 Replace the air valve cap back NOTE The cap is designed to be screwed on and off...

Page 12: ...ve Colder temperatures at night cause the spa to seem less inflated NOTE If there is a need to replace the spa tub air pressure release valve core 5 due to wear and tear use the included wrench 22 to unscrew the core from the valve base Replace a new air pressure release valve core back Make sure the core is securely tightened see drawing 8 Air expands in the midday heat and correct air pressure i...

Page 13: ...er use a damaged spa cover 6 Ensure the spa is plugged into an electrical socket and press the button to turn on the control unit panel buttons first Press the button on the control panel to activate the heater see Spa Control Unit Panel operation section IMPORTANT The following conditions will lead to slow water heating The ambient temperature is lower than 50ºF 10ºC Outdoor wind speed is above 8...

Page 14: ...The loss of salt is due only to SPA water being physically removed from the SPA Salt is not lost due to evaporation Adding Salt 1 Switch the JET pump on to start the water circulation 2 Keep the sanitation system turned off 3 Evenly spread 4 4 lbs 2 kg for 4 adults of salt around the inside perimeter of the SPA For six adults 5 5 lbs 2 5 kg of salt 4 Brush the SPA bottom to speed up the dissolving...

Page 15: ...lay for 5 seconds to confirm the new value NOTE The default temperature is 20 C 68 F NOTE Temperature adjustment ranges from 20 C 68 F to 40 C 104 F Water Filter Button This button turns the filter pump on and off If the heating system is activated the filtration system will automatically start The water filter icon on the display is green when activated Water Jet Button Use this button to activat...

Page 16: ...he water temperature Test the water with the included test strips and make sure the free chlorine level is between 2 4 ppm Note DO NOT press any other buttons on the control panel and attach the spa cover during the sanitizing process 3 Readjust operating time if necessary During the sanitizing process the operating hours can be re adjusted if necessary Press the sanitizer button the LED code 003H...

Page 17: ...fection pH values 4 Consider that the comfortable temperature range during use may be lower than the maximum safe temperature 5 Use the included insulating ground cloth underneath the spa to minimize heat loss through the bottom of the spa 6 Maintain clean filters to preserve appropriate working conditions for the pump and avoid unnecessary water replacement and re heating MINIMIZE HEAT LOSS AND E...

Page 18: ...arity clear view of the bottom Total Alkalinity TA in mg l 60 to 120 Calcium Hardness CaCO3 in mg l 150 to 250 Colour of the water no colour should be observedb c Turbidity in FNU NTU max 1 5 preferably less than 0 5 Nitrate concentration above that of fill water in mg l max difference of 20 compared to the fill water concentration Total organic carbon TOC in mg ld max 4 0 Redox potential against ...

Page 19: ...Result if too low Corroded metals eye skin irritation Low alkalinity will cause the pH to be unstable Result if too high Scale formation cloudy water shorter filter heater runs eye skin irritation high chlorine demand Calcium Hardness CaCO3 refers to the amount of calcium and magnesium dissolved in the water Result if too low Difficulty balancing water corrosion of metal components eye skin irrita...

Page 20: ...nd not the pH is higher than 120 ppm add appropriate chemical product to lower the TA level If the TA level is lower than 60 ppm add appropriate chemical product to raise the TA level NOTE After adjustment retest the water after 24 hours and adjust again if necessary pH Adjustment After the total alkalinity has been lowered to 120 ppm or raised to 80 ppm and the pH is still high or low add appropr...

Page 21: ... 2 Unscrew the filter cartridge assembly from the spa tub wall and use the included plugs 15 23 to cover the water inlet and outlet fittings from inside of the spa tub to prevent water from flowing out 3 Remove the four screws from the transparent cover using a Phillips screwdriver not included and remove the cover from the spa control unit Maintenance of Spa Water and Cartridge Protect all the sp...

Page 22: ...rolytic cell housing The Test Strips can test the Free Chlorine pH Total Alkalinity and Calcium Hardness levels at the same time We recommend that you test the water chemistry weekly and maintain the chlorine concentration at 2 4 ppm Directions and Use 1 Dip the entire strip into the water and remove immediately 2 Hold the strip level for 15 seconds Do not shake excess water from the strip 3 Now c...

Page 23: ...While empty remove the cartridge housing from inside of the spa tub wall clean and or replace the filter cartridge Use a sponge and mild soap solution to wipe away any soil or stains on the inside of the spa wall Rinse thoroughly before refilling with clean water IMPORTANT Do not use steel wool hard brushes or abrasive cleaners Biofilm Removal See your local spa professional for biofilm removal pr...

Page 24: ...nd spa cover air bladder 3 To deflate the tub and the cover air bladder a Open the deflation outlet cap 34 with the included bolt wrench 6 see drawing 17 b Insert deflation hose adaptor 35 into the deflation outlet c Insert inflation hose 7 over the deflation hose adaptor 35 d Insert the other end of the inflation hose into the tub air valve or cover air bladder valve e Press the air bubble button...

Page 25: ...again If problem persists contact Intex Service Center JETS OUTPUT ARE WEAK Low water level Obstruction in the suction inlet inside the tub Jet nozzles clogged or dirty Jet nozzles plumbing pipes damaged Add water between MIN and MAX level Ensure suction inlet is not covered or blocked Clean any dirt inside the jet nozzles Contact Intex Service Center JET AIR CONTROL KNOB NOT WORKING Jet nozzles c...

Page 26: ...emove grid from inside spa with a screwdriver ensure inlet outlet O ring is in place clean and not damaged SPA IS TOO NOISY IN FILTRATION MODE ONLY Control base components not securely attached Control base ground not level and firm Spa filter motor failed Ensure control panel back cover and all inlet outlet are securely connected Ensure ground is level firm and smooth Replace the failed filter mo...

Page 27: ...ance Add salt See Salt Level Information Ensure that the cell cord is plugged firmly into the cell receptacle Contact Intex Service Center Replace the cell if needed E92 High salt level Partially drain the pool and refill it with fresh water See Salt Level Information E94 Water temperature too low If the ambient temperature is below 4 C 39 F we recommend not to use the spa Turn off and unplug the ...

Page 28: ...u must drain out any remaining water inside the piping system of the control base before replacing any parts Tools required One adjustable wrench and one Philip screwdriver NOTE The special wrench tool is included with the new filter pump motor replacement and not with the spa set FILTER PUMP MOTOR DISASSEMBLY 1 2 3 4 5 6 ...

Page 29: ... by the provisions of the warranty the item will be repaired or replaced with the same or comparable item at Intex s choice at no charge to you Other than this warranty and other legal rights in your country no further warranties are implied To the extent possibly in your country in no event shall Intex be liable to you or any third party for direct or consequential damages arising out of the use ...

Reviews: