background image

(187IO)  MODEL ZS8220 & ZS8230  OZONE & SALTWATER SYSTEM  ENGLISH  7.5” X 10.3”  PANTONE 295U  08/01/2012

187A

    SAVE THESE INSTRUCTIONS

Page 11

English

INTEX POOLS SALT TABLE

This table shows the amount of salt needed to achieve and maintain the optimal 3000 ppm 

salt level.

Pool Size

Water Capacity (Calculated at 

90% for Frame Pool and 80% 

for Easy Set & Oval Pool)

Salt Needed for 

Startup

3.0g/L (3000ppm)

Salt Needed when

Low Salt Detected

(CODE “91”)

(Gals)

(Liters)

(Lbs)

(Kgs)

(Lbs)

(Kgs)

 INTEX ABOVE GROUND POOLS (AGP’s)

EASY SET® 

POOL

CIRCULAR

METAL

  

FRAME POOL

ULTRA 

FRAME®

POOL

SEQUOIA 

SPIRIT® 

POOL SET

OVAL FRAME

POOL

RECT. ULTRA

FRAME POOL

15' x 33" (457cm x 84cm)
15' x 36" (457cm x 91cm)

15' x 42" (457cm x 107cm)
15' x 48" (457cm x 122cm)
16' x 42" (488cm x 107cm)
16' x 48" (488cm x 122cm)
16' x 52" (488cm x 132cm)
18’ x 42” (549cm x 107cm)
18’ x 48” (549cm x 122cm)

15' x 36" (457cm x 91cm)

15' x 42" (457cm x 107cm)
15' x 48" (457cm x 122cm)
16' x 48" (488cm x 122cm)
18' x 48" (549cm x 122cm)
21' x 52" (640cm x 132cm)
24' x 52" (732cm x 132cm)
16' x 48" (488cm x 122cm)
18’ x 48” (549cm x 122cm)
18' x 52" (549cm x 132cm)
20’ x 48” (610cm x 122cm)
22’ x 52” (671cm x 132cm)
24’ x 52” (732cm x 132cm)
26’ x 52” (792cm x 132cm)

15’8” x 49” (478cm x 124cm)

16'8" x 49" (508cm x 124cm)
18'8" x 53" (569cm x 135cm)

18' x 10' x 42" (549cm x 305cm x 107cm)
20' x 12' x 48" (610cm x 366cm x 122cm)

15’ x 9’ x 48” (457cm x 274cm x 122cm)

18' x 9' x 52" (549cm x 274cm x 132cm)

20 x 10’ x 52” (610cm x 305cm x 132cm)

24' x 12' x 52" (732cm x 366cm x 132cm)
32' x 16' x 52" (975cm x 488cm x 132cm)

 2587 

9792 

65 

30 

20 

10

 2822 

10681 

65 

30 

20 

10

 3284 

12430 

80 

35 

20 

10

 3736 

14141 

95 

45 

25 

10

 3754 

14209 

95 

45 

25 

10

 4273 

16173  110 

50 

30 

15

 4614 

17464  115 

50 

30 

15

 4786 

18115  120 

55 

30 

15

 5455 

20647  135 

60 

35 

15

 3282 

12422 

80 

35 

20 

10

 3861 

14614  100 

45 

25 

10

 4440 

16805  110 

50 

30 

15

 5061 

19156  125 

55 

35 

15

 6423 

24311  160 

75 

40 

20

 9533  36082 240  110  60  30
 12481 

47241 

310 

140 

80 

35

 5061 

19156  125 

55 

35 

15

 6423 

24311  160 

75 

40 

20

 6981 

26423  175 

80 

45 

20

  7947  

30079  

210  

90  

50  

25 

  10472  

39637  

260  

120  

65  

30 

  12481  

47241  

310  

140  

80  

35 

  14667  

55515  

365  

165  

90  

40 

  4440  

16805  

110  

50  

30  

15 

  5061  

19156  

125  

55  

35  

15 

  6981  

26423  

175  

80  

45  

20 

  2885  

10920  

70  

30  

20  

10 

  4393  

16628  

110  

50  

30  

15

  3484  

13187  

90  

40  

25  

10 

  4545  

17203  

115  

50  

30  

15 

  5835  

22085  

145  

65  

40  

20 

  8403  

31805  

210  

95  

55  

25 

  14364  

54368  

360  

165  

90  

40 

Summary of Contents for Krystal Clear ZS8220

Page 1: ...oses only 187 A R0 1308 2012 Intex Marketing Ltd Intex Development Co Ltd Intex Trading Ltd Intex Recreation Corp All rights reserved Tous droits r serv s Todos los derechos reservados Alle Rechte vor...

Page 2: ...Pool Water Volumes 10 Intex Pools Salt Table 11 Intex Pools Cyanuric Acid Table 12 Intex Pools Operating Time Table 13 Non Intex Pools Salt Table 14 Non Intex Pools Cyanuric Acid Table 14 Non Intex P...

Page 3: ...e product The plug must be accessible after produc t is installed Do not bury the electrical cord Locate the cord where it will not be damaged by lawn mowers hedge trimmers and other equipment The sup...

Page 4: ...ATER SYSTEM ENGLISH 7 5 X 10 3 PANTONE 295U 08 01 2012 187A SAVE THESE INSTRUCTIONS Page 4 English PARTS LIST PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scal...

Page 5: ...SAVE THESE INSTRUCTIONS Page 5 English PARTS REFERENCE PARTS REFERENCE Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawi...

Page 6: ...1 10849 2 L SHAPE O RING 2 11228 3 SCREW 4 11519 4 TITANIUM ELECTRODE NUT 1 11432 5 TITANIUM ELECTRODE 1 11374 6 O RING ON TITANIUM PLATES 1 11515 7 FLOW SENSOR 1 11460 8 CONNECTOR HOSE WITH THREADED...

Page 7: ...troying bacteria and algae It also oxidizes all other organic materials Ozone is made by drawing air through Corona Discharge CD cells that break down oxygen molecules which then recombine into ozone...

Page 8: ...separate filter pump 1500 4000 gph 5680 15140 lph to drive the water and function properly The Ozone Saltwater System must be installed as the last piece of pool equipment in the water return line to...

Page 9: ...e filter pump outlet connection with a large hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Ozone Saltwater System to the pump connect it to the...

Page 10: ...of salt is due only to pool water being physically removed from the pool Salt is not lost due to evaporation Adding Salt 1 Switch the filter pump on to start the water circulation 2 Keep the Ozone Sal...

Page 11: ...49cm x 132cm 20 x 48 610cm x 122cm 22 x 52 671cm x 132cm 24 x 52 732cm x 132cm 26 x 52 792cm x 132cm 15 8 x 49 478cm x 124cm 16 8 x 49 508cm x 124cm 18 8 x 53 569cm x 135cm 18 x 10 x 42 549cm x 305cm...

Page 12: ...0cm x 122cm 7947 30079 2 0 0 9 22 x 52 671cm x 132cm 10472 39637 2 6 1 2 24 x 52 732cm x 132cm 12481 47241 3 1 1 4 26 x 52 792cm x 132cm 14667 55515 3 7 1 7 SEQUOIA SPIRIT POOL SET 15 8 x 49 478cm x 1...

Page 13: ...x 52 549cm x 132cm 20 x 48 610cm x 122cm 22 x 52 671cm x 132cm 24 x 52 732cm x 132cm 26 x 52 792cm x 132cm 15 8 x 49 478cm x 124cm 16 8 x 49 508cm x 124cm 18 8 x 53 569cm x 135cm 18 x 10 x 42 549cm x...

Page 14: ...artup Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0...

Page 15: ...e The built in timer will now activate your Ozone Saltwater System at the same time each day for the number of hours you have set NOTE The Ozone Saltwater System will not operate if the filter pump is...

Page 16: ...s operating check whether the filter pump operating hours have been set properly For example the boost operating time is 16 hours the filter pump should be set to run for 17 hours at least Increase th...

Page 17: ...urs remaining 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours...

Page 18: ...ere is a regulation in your area regarding above the ground swimming pool filter pumps If yes then the product can be mounted to a platform using the two holes located in the base See drawing below Th...

Page 19: ...power cord back in and open the plunger valves or remove the plugs Ozone generator assembly replacement 1 The REPLACE O3 GENERATOR light on the panel will turn red when the Ozone generator assembly n...

Page 20: ...ening the sensor back into its position Do not overtighten Electrolytic Cell Cleaning The electrolytic cell has a self cleaning function incorporated into the electronic control s programming In most...

Page 21: ...Read and follow the written strip instructions carefully 1 Disconnect the power cord from the electrical outlet 2 After the pool is completely empty disconnect the Ozone Saltwater System from the hos...

Page 22: ...affect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved in the water Result i...

Page 23: ...s Add appropriate stabilizer See Cyanuric Acid table Use a pool cover when the pool is not in use and or when the unit is operating Increase the daily Ozone Saltwater System operating time See Operati...

Page 24: ...n the circulation line See the filter pump manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying special atten...

Page 25: ...ll risks and dangers For additional safeguards also familiarize yourself with the following general guidelines as well as guidelines provided by nationally recognized Safety Organizations Demand const...

Page 26: ...in the periods noted above please contact the appropriate Intex Service Center listed in the separate Authorized Service Centers sheet The Service Center will determine the validity of the claim IMPLI...

Reviews: