background image

(187PO)  MODEL ZS8110  OZONE & SALTWATER SYSTEM  ENGLISH  7.5” X 10.3”  PANTONE 295U  06/28/2013

187

PO

    

SAVE THESE INSTRUCTIONS

English

Page 23

Your Krystal Clear

TM

 Ozone & Saltwater System has been manufactured using the 

highest quality  materials and workmanship. All Intex products have been inspected 
and found free of defects prior to leaving the factory. This Limited Warranty applies 
only to the Krystal Clear

TM

 Ozone & Saltwater System

 

and accessories listed below.

The provisions of this Limited Warranty apply only to the original purchaser and is 
not transferable. This Limited Warranty is valid for the period noted below from the 
date of the initial retail purchase. Keep your original sales receipt with this manual, 
as proof of purchase will be required and must accompany warranty claims or the 
Limited Warranty is invalid.                                                                                

 

 Krystal 

Clear

TM

 Ozone & Saltwater System Warranty – 2 Years

 

Titanium electrode & Ozone generator assembly Warranty – 1 Year                                    

 

Hoses, Plunger Valves & Fittings Warranty – 180 days

If a manufacturing defect is found within the periods noted above, please contact the 
appropriate Intex Service Center listed in the separate “Authorized Service Centers” 
sheet. The Service Center will determine the validity of the claim. If the Service 
Center directs you to return the product, please carefully package the product and 
send with shipping and insurance prepaid to the Service Center. Upon receipt of the 
returned product, the Intex Service Center will inspect the item and determine the 
validity of the claim. If the provisions of this warranty cover the item, the item will be 
repaired or replaced at no charge.  

Any and all disputes regarding the provisions of this Limited Warranty shall be 
brought before an informal dispute settlement board and unless and until the
provisions of these paragraphs are carried forth, no civil action may be instituted. 
The methods and procedures of this settlement board shall be subject to the rules 
and regulations set forth by the Federal Trade Commission (F.T.C.). IMPLIED          
WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN 
NO EVENT SHALL INTEX, THEIR AUTHORIZED AGENTS OR EMPLOYEES 
BE  LIABLE  TO  THE  BUYER  OR  ANY  OTHER  PARTY  FOR  DIRECT  OR                         
CONSEQUENTIAL DAMAGES OR LIABILITIES. Some states, or jurisdictions do 
not allow the exclusion or limitation of incidental or consequential damages, so the 
above limitation or exclusion may not apply to you.  

This Limited Warranty does not apply if the products are subject to negligence, 
abnormal use or operation, accident, improper operation, improper voltage or current 
contrary to operating instructions, or to damage by circumstances beyond Intex’s 
control, including but not limited to, ordinary wear and tear and damage caused by 
exposure to fire, flood, freezing, rain, or other external environmental forces. This 
Limited Warranty applies only to those parts and components sold by Intex. The 
Limited Warranty does not cover unauthorized alterations, repairs or disassembly by 
anyone other than Intex Service Center personnel.

DO NOT GO BACK TO THE PLACE OF PURCHASE FOR RETURN OR 
REPLACEMENT. IF YOU ARE MISSING PARTS OR NEED ASSISTANCE, 
PLEASE CALL US TOLL-FREE (FOR U.S. AND CANADIAN RESIDENTS): 
1-800-234-6839 OR VISIT OUR WEBSITE: WWW.INTEXSTORE.COM. 

Proof of Purchase must accompany all returns or the warranty claim will be invalid.

LIMITED WARRANTY

Summary of Contents for Krystal Clear ZS8110

Page 1: ...me Toys Airbeds and Boats available at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may...

Page 2: ...Volumes 8 Intex Pools Salt Table 9 Intex Pools Cyanuric Acid Table 10 Intex Pools Operating Time Table 11 Non Intex Pools Salt Table 12 Non Intex Pools Cyanuric Acid Table 12 Non Intex Pools Operating...

Page 3: ...replaced immediately To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet Do no...

Page 4: ...cale 1 6 7 4 9 8 2 3 2 5 10 11 When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 ADAPTOR A WITH THREADED COLLAR OPTIONAL 1 10849 2 L SHAPE O...

Page 5: ...It also oxidizes all other organic materials Ozone is made by drawing air through Corona Discharge CD cells that break down oxygen molecules which then recombine into ozone molecules Ozone gas is intr...

Page 6: ...e filter pump 1500 4000 gph 5680 15140 lph to drive the water and function properly The Ozone Saltwater System must be installed as the last piece of pool equipment in the water return line to the poo...

Page 7: ...p outlet connection with a large hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Ozone Saltwater System to the pump connect it to the pool This is...

Page 8: ...only to pool water being physically removed from the pool Salt is not lost due to evaporation Adding Salt 1 Switch the filter pump on to start the water circulation 2 Keep the Ozone Saltwater System t...

Page 9: ...00 45 25 10 15 x 48 457cm x 122cm 4440 16805 110 50 30 15 16 x 48 488cm x 122cm 5061 19156 125 55 35 15 18 x 48 549cm x 122cm 6423 24311 160 75 40 20 21 x 52 640cm x 132cm 9533 36082 240 110 60 30 24...

Page 10: ...x 122cm 7947 30079 2 0 0 9 22 x 52 671cm x 132cm 10472 39637 2 6 1 2 24 x 52 732cm x 132cm 12481 47241 3 1 1 4 26 x 52 792cm x 132cm 14667 55515 3 7 1 7 SEQUOIA SPIRIT POOL SET 15 8 x 49 478cm x 124c...

Page 11: ...05 2 2 3 4 16 x 48 488cm x 122cm 5061 19156 2 3 4 6 18 x 48 549cm x 122cm 6423 24311 3 3 4 6 21 x 52 640cm x 132cm 9533 36082 4 5 6 8 24 x 52 732cm x 132cm 12481 47241 5 6 7 8 ULTRA FRAME POOL 16 x 48...

Page 12: ...up Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 00...

Page 13: ...timer will now activate your Ozone Saltwater System at the same time each day for the number of hours you have set NOTE The Ozone Saltwater System will not operate if the filter pump is not operating...

Page 14: ...eck whether the filter pump operating hours have been set properly For example the boost operating time is 16 hours the filter pump should be set to run for 17 hours at least Increase the filter pump...

Page 15: ...ing 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining...

Page 16: ...ord back in and open the plunger valves or remove the plugs Ozone generator assembly replacement 1 The REPLACE O3 GENERATOR light on the panel will turn red when the Ozone generator assembly need to b...

Page 17: ...sensor back into its position Do not overtighten Electrolytic Cell Cleaning The electrolytic cell has a self cleaning function incorporated into the electronic control s programming In most cases thi...

Page 18: ...follow the written strip instructions carefully 1 Disconnect the power cord from the electrical outlet 2 After the pool is completely empty disconnect the Ozone Saltwater System from the hoses by rev...

Page 19: ...he water will have an affect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved...

Page 20: ...the cell housing receptacle Find out the switch and turn on Reset the RCD GFCI Contact Intex Service Center PROBLEM CAUSE SOLUTION IMPORTANT If you continue to experience difficulty please contact ou...

Page 21: ...ed air in the circulation line See the filter pump manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying speci...

Page 22: ...im Take the time to learn CPR and first aid Instruct anyone who is supervising pool users about potential pool hazards and about the use of protective devices such as locked doors barriers etc Instruc...

Page 23: ...e item will be repaired or replaced at no charge Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and unti...

Reviews: