TROUBLESHOOTING GUIDE (continued)
1.
Filter pump not attached to
system and/or switch on.
2
. Circulation line is blocked.
3
. Incorrect inlet and outlet hose
direction.
4
. Scale on the flow sensor.
5
. Flow sensor cord is loose.
6
. Inner timer conflict between filter pump
and Ozone & saltwater system.
7
. Flow sensor failure.
1
. Dirt or scale on titanium plates.
2
. Low salt level / No salt.
3
. Electrolytic cell cord is loose.
4
. Possible electrolytic cell failure.
1
. High salt level.
1
. Display and all lights are off - the
system does not power up.
1
. Ozone generator assembly
failure.
•
Ensure filter pump is attached and operating.
See "Setup Instruction".
•
If your unit has plunger valves, ensure that
they are open.
•
Clear your filter cartridge and cell from debris
and dirt. See “Maintenance”.
•
Release all trapped air in the circulation line.
See the filter pump manual.
•
Check the direction of the inlet and the outlet
hose. Reverse the hoses if necessary. See “Set
Up
Instructions”.
•
Clean the flow sensor, paying special attention
to the hinge. See “Maintenance”.
•
Plug the flow sensor firmly into the flow
sensor
receptacle.
•
Reset both timers on the filter pump and
Ozone & Saltwater System.
•
Contact Intex Service Center.
•
Remove the electrolytic cell for inspection.
Clean it if necessary. See “Maintenance”.
•
Add salt. See “Salt & Pool Water Volumes”.
•
Ensure that the cell cord is plugged firmly into
the cell housing receptacle.
•
Contact Intex Service Center. Replace the cell
if
needed.
•
Partially drain the pool and refill it with fresh
water. See “Salt & Pool Water Volumes”.
•
Household voltage is too high or too low
(+ 20%). Check the voltage is within the
range stated on the device housing.
•
Contact Intex Service Center.
•
Contact Intex Service Center. Replace
the assembly following the relevant
instruction in maintenance section.
LED PANEL
CODE
PROBLEM
SOLUTION
LED Panel Code Flash & Alarm On (
NOTE
: Always turn off the power before cleaning and servicing).