TROUBLESHOOTING GUIDE

INSUFFICIENT 
CHLORINE

WHITE FLAKES IN 
THE WATER

NO LED DISPLAY

• 

Insufficient operating hours of  

  the Ozone & Saltwater System.

• 

The salt level in the pool water 

  is less than 2000ppm. This is  
 insufficient.

• 

Chlorine loss due to intense  

 sunlight 

exposure.

• 

The bather load has increased.

• 

Clogged or dirty electrolytic cell.

• 

High UV level exposure.

• 

Excessive calcium hardness is  

  present in pool water.  

  No power supply.

•  RCD/GFCI has not reseted.

• 

A power fuse has blown.

• 

LED failure.  

• 

Increase the daily Ozone & Saltwater System 

  operating time. See “Operating Instructions”.  

• 

Check the salt level with the Test Kit. Adjust as 

  needed. See “Salt & Pool Water Volumes”.

• 

Add appropriate stabilizer. See “Cyanuric Acid 

 table”.

  Use a pool cover when the pool is not in use and/

  or when the unit is operating. 

  Increase the daily Ozone & Saltwater System 

  operating time. See “Operating Instructions”.

  Remove the cell for inspection, clean it if necessary.  

 See 

“Maintenance”.

  Cover the pool with a pool cover for 2 days  

  with the device running and then test the 
  water using the test strips.

  If the pool is clean and clear, add stabilizer to the  

  water and then test the water with the device running.

  Drain about 20 to 25% of the pool water and  

  add fresh water to decrease the calcium 
  hardness. Inspect the electrolytic cell for 
  scale buildup. Clean the electrolytic cell if
  

necessary.

  Plug the cell cord firmly into the cell housing  

 receptacle.

• 

Find out the switch and turn on.

  Reset the RCD/GFCI.

  Contact Intex Service Center.

PROBLEM                               CAUSE                                             SOLUTION

IMPORTANT

If you continue to experience difficulty, please contact our Consumer Service 
Department for assistance. See separate “Authorized Service Centers” sheet.

Operation is subject to the following two conditions: 

(1)

 this device may not cause interference, and 

(2)

 

this device must accept any interference, including interference that may cause undesired operation 
of the device. 

Changes or modifications not expressly approved by the party responsible for compliance could void 
the user’s authority to operate the equipment. 

This equipment has been tested and found to comply with the limits for Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the following 
measures:

  Reorient or relocate the receiving antenna.

   Increase the separation between the equipment and the receiver. 

  Connect the equipment into an outlet on a circuit different from that to which the receiver is  

 

 connected.

  Consult the dealer or an experienced radio/TV technician for help.

Summary of Contents for Krystal Clear ZS8110

Page 1: ...me Toys Airbeds and Boats available at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may...

Page 2: ...Volumes 8 Intex Pools Salt Table 9 Intex Pools Cyanuric Acid Table 10 Intex Pools Operating Time Table 11 Non Intex Pools Salt Table 12 Non Intex Pools Cyanuric Acid Table 12 Non Intex Pools Operating...

Page 3: ...replaced immediately To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet Do no...

Page 4: ...cale 1 6 7 4 9 8 2 3 2 5 10 11 When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 ADAPTOR A WITH THREADED COLLAR OPTIONAL 1 10849 2 L SHAPE O...

Page 5: ...It also oxidizes all other organic materials Ozone is made by drawing air through Corona Discharge CD cells that break down oxygen molecules which then recombine into ozone molecules Ozone gas is intr...

Page 6: ...e filter pump 1500 4000 gph 5680 15140 lph to drive the water and function properly The Ozone Saltwater System must be installed as the last piece of pool equipment in the water return line to the poo...

Page 7: ...p outlet connection with a large hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Ozone Saltwater System to the pump connect it to the pool This is...

Page 8: ...only to pool water being physically removed from the pool Salt is not lost due to evaporation Adding Salt 1 Switch the filter pump on to start the water circulation 2 Keep the Ozone Saltwater System t...

Page 9: ...00 45 25 10 15 x 48 457cm x 122cm 4440 16805 110 50 30 15 16 x 48 488cm x 122cm 5061 19156 125 55 35 15 18 x 48 549cm x 122cm 6423 24311 160 75 40 20 21 x 52 640cm x 132cm 9533 36082 240 110 60 30 24...

Page 10: ...x 122cm 7947 30079 2 0 0 9 22 x 52 671cm x 132cm 10472 39637 2 6 1 2 24 x 52 732cm x 132cm 12481 47241 3 1 1 4 26 x 52 792cm x 132cm 14667 55515 3 7 1 7 SEQUOIA SPIRIT POOL SET 15 8 x 49 478cm x 124c...

Page 11: ...05 2 2 3 4 16 x 48 488cm x 122cm 5061 19156 2 3 4 6 18 x 48 549cm x 122cm 6423 24311 3 3 4 6 21 x 52 640cm x 132cm 9533 36082 4 5 6 8 24 x 52 732cm x 132cm 12481 47241 5 6 7 8 ULTRA FRAME POOL 16 x 48...

Page 12: ...up Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 00...

Page 13: ...timer will now activate your Ozone Saltwater System at the same time each day for the number of hours you have set NOTE The Ozone Saltwater System will not operate if the filter pump is not operating...

Page 14: ...eck whether the filter pump operating hours have been set properly For example the boost operating time is 16 hours the filter pump should be set to run for 17 hours at least Increase the filter pump...

Page 15: ...ing 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining...

Page 16: ...ord back in and open the plunger valves or remove the plugs Ozone generator assembly replacement 1 The REPLACE O3 GENERATOR light on the panel will turn red when the Ozone generator assembly need to b...

Page 17: ...sensor back into its position Do not overtighten Electrolytic Cell Cleaning The electrolytic cell has a self cleaning function incorporated into the electronic control s programming In most cases thi...

Page 18: ...follow the written strip instructions carefully 1 Disconnect the power cord from the electrical outlet 2 After the pool is completely empty disconnect the Ozone Saltwater System from the hoses by rev...

Page 19: ...he water will have an affect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved...

Page 20: ...the cell housing receptacle Find out the switch and turn on Reset the RCD GFCI Contact Intex Service Center PROBLEM CAUSE SOLUTION IMPORTANT If you continue to experience difficulty please contact ou...

Page 21: ...ed air in the circulation line See the filter pump manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying speci...

Page 22: ...im Take the time to learn CPR and first aid Instruct anyone who is supervising pool users about potential pool hazards and about the use of protective devices such as locked doors barriers etc Instruc...

Page 23: ...e item will be repaired or replaced at no charge Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and unti...

Reviews: