background image

(187PO)  MODEL ZS8110  OZONE & SALTWATER SYSTEM  ENGLISH  7.5” X 10.3”  PANTONE 295U  06/28/2013

187

PO

    

SAVE THESE INSTRUCTIONS

English

Page 19

POOL MAINTENANCE & CHEMICAL DEFINITIONS

 

Free Chlorine

 -

 

  Is the chlorine residual present in pool water.

 

Combined Chlorine

 -

 

  Is formed by the reaction of free chlorine with ammonia wastes.

 

  Result if too high -  Sharp chlorinous odor, eye irritation.

 

pH

 - 

 

A value that indicates how acidic or basic a solution is.

 

  Result if too low -  Corroded metals, eye & skin irritation,  

 

 

   

destruction of total alkalinity.

 

  Result if too high -  Scale formation, cloudy water, shorter  

 

 

   

filter runs, eye & skin irritation, poor chlorine 

  

 

efficiency.

 

Total Alkalinity

 -

  Indicates the degree of the water's resistance to change  

 

 

  in pH. It determines the speed and ease of pH change, so always 

 

  adjust total alkalinity before adjusting the pH level.

 

  Result if too low -  Corroded metals, eye & skin irritation.  

 

 

   

Low alkalinity will cause the pH to be unstable. 

 

   

Any chemical added to the water will have an 

 

   

affect on pH.

 

  Result if too high -  Scale formation, cloudy water, eye & skin irritation,  

 

   

poor chlorine efficiency.

 

Calcium Hardness

 -

  Refers to the amount of calcium and magnesium dissolved in the water.

 

  Result if too high -  Scale will form and will cause the water to 

  

 

become 

cloudy.

 

Stabilizer

 -

 

  Stabilizers extend the life of chlorine in swimming pools.

 

 

(Cyanuric Acid)

 

•  Do not add pool chemicals directly to the skimmer. This may damage the cell.
•  Maintaining a salt and sanitizer level above the recommended range can contribute to the  
  corrosion of the pool equipment.
•  Check the expiry date of the test kit as the test results may be inaccurate if the kit is used  
  after that date.
•  If, due to heavy pool usage, it is required to increase the sanitizer level, then use a chemical  
  based on Trichloro-s-triazinetrione or sodium dichloro-s-triazinetrione dihydrate.

Preferred Water Chemistry Reading

 

   Minimum 

 Ideal 

 Maximum

Free Chlorine

 

0.5 - 3 ppm 

5.0 ppm

Combined Chlorine

 

0 ppm 

0.2 ppm

pH

 

7.2 

7.4 - 7.6 

7.8

Total Alkalinity

 

100 ppm 

100 - 140 ppm 

140 ppm

Calcium Hardness

 

150 ppm 

200 - 400 ppm 

500 - 1000 ppm

Stabilizer (Cyanuric Acid)

 

10 ppm 

20 - 40 ppm 

50 ppm

Summary of Contents for Krystal Clear ZS8110

Page 1: ...me Toys Airbeds and Boats available at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may...

Page 2: ...Volumes 8 Intex Pools Salt Table 9 Intex Pools Cyanuric Acid Table 10 Intex Pools Operating Time Table 11 Non Intex Pools Salt Table 12 Non Intex Pools Cyanuric Acid Table 12 Non Intex Pools Operating...

Page 3: ...replaced immediately To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet Do no...

Page 4: ...cale 1 6 7 4 9 8 2 3 2 5 10 11 When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 ADAPTOR A WITH THREADED COLLAR OPTIONAL 1 10849 2 L SHAPE O...

Page 5: ...It also oxidizes all other organic materials Ozone is made by drawing air through Corona Discharge CD cells that break down oxygen molecules which then recombine into ozone molecules Ozone gas is intr...

Page 6: ...e filter pump 1500 4000 gph 5680 15140 lph to drive the water and function properly The Ozone Saltwater System must be installed as the last piece of pool equipment in the water return line to the poo...

Page 7: ...p outlet connection with a large hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Ozone Saltwater System to the pump connect it to the pool This is...

Page 8: ...only to pool water being physically removed from the pool Salt is not lost due to evaporation Adding Salt 1 Switch the filter pump on to start the water circulation 2 Keep the Ozone Saltwater System t...

Page 9: ...00 45 25 10 15 x 48 457cm x 122cm 4440 16805 110 50 30 15 16 x 48 488cm x 122cm 5061 19156 125 55 35 15 18 x 48 549cm x 122cm 6423 24311 160 75 40 20 21 x 52 640cm x 132cm 9533 36082 240 110 60 30 24...

Page 10: ...x 122cm 7947 30079 2 0 0 9 22 x 52 671cm x 132cm 10472 39637 2 6 1 2 24 x 52 732cm x 132cm 12481 47241 3 1 1 4 26 x 52 792cm x 132cm 14667 55515 3 7 1 7 SEQUOIA SPIRIT POOL SET 15 8 x 49 478cm x 124c...

Page 11: ...05 2 2 3 4 16 x 48 488cm x 122cm 5061 19156 2 3 4 6 18 x 48 549cm x 122cm 6423 24311 3 3 4 6 21 x 52 640cm x 132cm 9533 36082 4 5 6 8 24 x 52 732cm x 132cm 12481 47241 5 6 7 8 ULTRA FRAME POOL 16 x 48...

Page 12: ...up Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 00...

Page 13: ...timer will now activate your Ozone Saltwater System at the same time each day for the number of hours you have set NOTE The Ozone Saltwater System will not operate if the filter pump is not operating...

Page 14: ...eck whether the filter pump operating hours have been set properly For example the boost operating time is 16 hours the filter pump should be set to run for 17 hours at least Increase the filter pump...

Page 15: ...ing 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining...

Page 16: ...ord back in and open the plunger valves or remove the plugs Ozone generator assembly replacement 1 The REPLACE O3 GENERATOR light on the panel will turn red when the Ozone generator assembly need to b...

Page 17: ...sensor back into its position Do not overtighten Electrolytic Cell Cleaning The electrolytic cell has a self cleaning function incorporated into the electronic control s programming In most cases thi...

Page 18: ...follow the written strip instructions carefully 1 Disconnect the power cord from the electrical outlet 2 After the pool is completely empty disconnect the Ozone Saltwater System from the hoses by rev...

Page 19: ...he water will have an affect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved...

Page 20: ...the cell housing receptacle Find out the switch and turn on Reset the RCD GFCI Contact Intex Service Center PROBLEM CAUSE SOLUTION IMPORTANT If you continue to experience difficulty please contact ou...

Page 21: ...ed air in the circulation line See the filter pump manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying speci...

Page 22: ...im Take the time to learn CPR and first aid Instruct anyone who is supervising pool users about potential pool hazards and about the use of protective devices such as locked doors barriers etc Instruc...

Page 23: ...e item will be repaired or replaced at no charge Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and unti...

Reviews: