MAINTENANCE (continued)

The 3-Way Test Strips can test the “Free Chlorine”, “pH”, and “Total Alkalinity” levels at the 
same time. We recommend that you test the water chemistry weekly, and maintain the chlorine 
concentration at 0.5-3 ppm.

Directions and Use
1

.   Dip the entire strip into the water and remove immediately.

2

.   Hold the strip level for 15 seconds. Do  not shake excess water from the strip.

3

.   Now compare the strip pad to the color chart on the packaging label. If necessary, adjust  

 

the chemical level in the pool water. It is very important, to use the proper technique when  

 

testing the water's chemical level. Read and follow the written strip instructions carefully.

1

.   Disconnect the power cord from the electrical outlet.

2

.   After the pool is completely empty, disconnect the Ozone & Saltwater System from the  

 

hoses by reversing the installation instructions. 

3

.   Air-dry the unit before you store it. This might be a good time to visually inspect and clean  

 

the electrolytic cell.

4

.   Store the unit and accessories in a dry place. The temperature should be controlled,  

 

between 32 degrees Fahrenheit (0 degrees Celsius) and 97  degrees Fahrenheit (36   

 degrees 

Celsius).

5

.   The original package can be used for storage.

INTEX

®

 3-WAY TEST STRIPS

 

(PACKED WITH THE PRODUCT)

LONG TERM STORAGE

4. 

In a counter-clockwise motion, unscrew the Titanium electrode nut 

(4)

. Pull out the Titanium  

 electrode 

(5)

.

5. 

Pour kitchen grade vinegar into a mug to immerse the titanium plates. Soak  them for about  

 

one hour and then flush with a garden hose. 

6.

  Reverse steps 3 and 4 to replace the Titanium electrode 

(5)

.

Summary of Contents for Krystal Clear ZS8110

Page 1: ...me Toys Airbeds and Boats available at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may...

Page 2: ...Volumes 8 Intex Pools Salt Table 9 Intex Pools Cyanuric Acid Table 10 Intex Pools Operating Time Table 11 Non Intex Pools Salt Table 12 Non Intex Pools Cyanuric Acid Table 12 Non Intex Pools Operating...

Page 3: ...replaced immediately To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet Do no...

Page 4: ...cale 1 6 7 4 9 8 2 3 2 5 10 11 When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 ADAPTOR A WITH THREADED COLLAR OPTIONAL 1 10849 2 L SHAPE O...

Page 5: ...It also oxidizes all other organic materials Ozone is made by drawing air through Corona Discharge CD cells that break down oxygen molecules which then recombine into ozone molecules Ozone gas is intr...

Page 6: ...e filter pump 1500 4000 gph 5680 15140 lph to drive the water and function properly The Ozone Saltwater System must be installed as the last piece of pool equipment in the water return line to the poo...

Page 7: ...p outlet connection with a large hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Ozone Saltwater System to the pump connect it to the pool This is...

Page 8: ...only to pool water being physically removed from the pool Salt is not lost due to evaporation Adding Salt 1 Switch the filter pump on to start the water circulation 2 Keep the Ozone Saltwater System t...

Page 9: ...00 45 25 10 15 x 48 457cm x 122cm 4440 16805 110 50 30 15 16 x 48 488cm x 122cm 5061 19156 125 55 35 15 18 x 48 549cm x 122cm 6423 24311 160 75 40 20 21 x 52 640cm x 132cm 9533 36082 240 110 60 30 24...

Page 10: ...x 122cm 7947 30079 2 0 0 9 22 x 52 671cm x 132cm 10472 39637 2 6 1 2 24 x 52 732cm x 132cm 12481 47241 3 1 1 4 26 x 52 792cm x 132cm 14667 55515 3 7 1 7 SEQUOIA SPIRIT POOL SET 15 8 x 49 478cm x 124c...

Page 11: ...05 2 2 3 4 16 x 48 488cm x 122cm 5061 19156 2 3 4 6 18 x 48 549cm x 122cm 6423 24311 3 3 4 6 21 x 52 640cm x 132cm 9533 36082 4 5 6 8 24 x 52 732cm x 132cm 12481 47241 5 6 7 8 ULTRA FRAME POOL 16 x 48...

Page 12: ...up Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 00...

Page 13: ...timer will now activate your Ozone Saltwater System at the same time each day for the number of hours you have set NOTE The Ozone Saltwater System will not operate if the filter pump is not operating...

Page 14: ...eck whether the filter pump operating hours have been set properly For example the boost operating time is 16 hours the filter pump should be set to run for 17 hours at least Increase the filter pump...

Page 15: ...ing 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining...

Page 16: ...ord back in and open the plunger valves or remove the plugs Ozone generator assembly replacement 1 The REPLACE O3 GENERATOR light on the panel will turn red when the Ozone generator assembly need to b...

Page 17: ...sensor back into its position Do not overtighten Electrolytic Cell Cleaning The electrolytic cell has a self cleaning function incorporated into the electronic control s programming In most cases thi...

Page 18: ...follow the written strip instructions carefully 1 Disconnect the power cord from the electrical outlet 2 After the pool is completely empty disconnect the Ozone Saltwater System from the hoses by rev...

Page 19: ...he water will have an affect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved...

Page 20: ...the cell housing receptacle Find out the switch and turn on Reset the RCD GFCI Contact Intex Service Center PROBLEM CAUSE SOLUTION IMPORTANT If you continue to experience difficulty please contact ou...

Page 21: ...ed air in the circulation line See the filter pump manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying speci...

Page 22: ...im Take the time to learn CPR and first aid Instruct anyone who is supervising pool users about potential pool hazards and about the use of protective devices such as locked doors barriers etc Instruc...

Page 23: ...e item will be repaired or replaced at no charge Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and unti...

Reviews: