1. 

Make sure the filter pump is switched off. The switch is located on the motor housing.

2.

  Connect the power cord to a GFCI protected electrical outlet.

 

3

.

 

Turn both plunger valve handles fully counter-clockwise until they stop. This opens the  

 

valve, allowing water to flow into the filter pump.  

4

.  With water flowing into filter pump, the water pressure will allow the air trapped inside to  

 

escape from the air release valve 

(2).

 When all the air has escaped water will flow out of the  

 valve 

(2). 

When this occurs gently finger tighten the valve

 (2) 

in a clockwise direction.

5.   To operate the filter pump on “TIMER” mode:

 

A.   Set the timer dial to the desired operating hours. See operation time table. See Fig. 10

 

B.   Turn on the pump by pressing the switch to “    ” position, the filter pump is now filtering  

 

 

 the water and will stop after the operating hours are completed. The built-in timer will  

 

 

 now operate for the number of hours selected at the same time each day.

 

C.   Operating hours can be re-adjusted if necessary. Follow step A – B.

 

To operate the filter pump manually (without the “TIMER” mode):

 

A.   Turn on the pump by pressing the switch to “-” position, the filter pump is now filtering  

   

the 

water.

 

B.   To turn off the pump, press the switch to “O” position.

To prevent air lock, open the lower plunger valve (connected inlet hose) first and 
then the upper plunger valve (connected outlet hose). Open the air release valve, 
wait until water starts to flow out of the air release valve, close air release valve.

IMPORTANT

OPERATING INSTRUCTIONS

Risk of electric shock. Connect this product only to a grounding type 

receptacle protected by a ground-fault circuit interrupter (GFCI) or 

residual current device (RCD). Contact a qualified electrician if you 

cannot verify that the receptacle is protected by a GFCI/RCD. Use a 

qualified electrician to install the GFCI/RCD, which has a maximum rate 

of 30mA. Do not use a portable residual current device (PRCD).

WARNING

12

ON

OFF TIMER

FIG 10

TIMER DIAL (HOURS)

6

.

 

Never put pool chemicals directly into the filter pump. This may damage the pump and void 

 the 

warranty. 

Summary of Contents for krystal clear 636T

Page 1: ...served Tous droits r serv s Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world und...

Page 2: ...English Page 2 Warnings 3 Parts Reference 4 5 Setup Instructions 6 9 Operating Instructions 10 Operating Time Table 11 Maintenance 12 13 Pool Care and Chemicals 13 Long Term Storage 13 Troubleshootin...

Page 3: ...e damaged by lawn mowers hedge trimmers and other equipment If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a h...

Page 4: ...hen ordering parts be sure to quote the model number and part numbers 1 2 3 4 5 6 7 REF NO DESCRIPTION QTY SPARE PART NO 1 2 2 1 1 1 2 THREADED FILTER HOUSING COLLAR AIR RELEASE VALVE SEDIMENT RELEASE...

Page 5: ...11 12 13 14 REF NO DESCRIPTION QTY SPARE PART NO 2 2 2 2 1 PLUNGER VALVE HOSE O RING STEP WASHER INCLUDED HOSE O RING STEP WASHER STRAINER NUT FLAT STRAINER RUBBER WASHER THREADED STRAINER CONNECTOR A...

Page 6: ...screw the strainer nut 11 back onto the threaded connector 13 see drawing 2 5 Finger tighten the strainer nut 11 onto the threaded connector 13 6 Grasp the plunger valve assembly Make sure the step wa...

Page 7: ...e strainer nut 11 facing the outside wall of the liner in a clockwise motion screw the strainer nut 11 back onto the threaded connector 13 see drawing 6 5 Finger tighten the adjustable pool inlet nozz...

Page 8: ...cover 4 Check to see if a cartridge is inside the housing If yes replace the cover finger tighten the housing collar 1 back onto the filter housing 7 Gently finger tighten the sediment release valve l...

Page 9: ...cal authorities to determine if there is a regulation in your area regarding above the ground swimming pool filter pumps If yes then the filter pump can be mounted to a platform using the two holes lo...

Page 10: ...ow operate for the number of hours selected at the same time each day C Operating hours can be re adjusted if necessary Follow step A B To operate the filter pump manually without the TIMER mode A Tur...

Page 11: ...AGP s EASY SET POOL 18 x 42 549cm x 107cm 4 786 18 115 4 18 x 48 549cm x 122cm 5 455 20 647 6 CIRCULAR METAL FRAME POOL 18 x 48 549cm x 122cm 6 423 24 311 6 21 x 52 9 533 36 082 8 ULTRA FRAME POOL 16...

Page 12: ...e the used filter cartridge 7 Examine the inside of the filter housing 8 If dirt or sediment is located on the bottom of the housing then A In a counter clockwise motion gently unscrew and remove the...

Page 13: ...and usage level Experiment with various run times so as to produce clean clear water CAUTION Concentrated chlorine solutions may damage the pool liner Always follow the chemical manufacturer s direct...

Page 14: ...LE CAUSE SOLUTION Filter cord must be plugged into a 3 wire outlet that is protected by a Class A Ground Fault Circuit Interrupter or RCD Reset circuit breaker If circuit breaker trips repeatedly your...

Page 15: ...pool liner Pool liner is slippery and or has a bad odor Water turns blue brown or black when first treated with chlorine Water is cloudy or milky Level is lower than on previous day Dirt or sand on po...

Page 16: ...propriate Intex Service Center listed in the separate Authorized Service Centers sheet The Service Center will determine the validity of the claim IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS W...

Reviews: