background image

English

57CD

    

SAVE THESE INSTRUCTIONS

English

(57CD)  MODEL 603 FILTER PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  06/15/2016

Page 8

TROUBLESHOOTING GUIDE

•  Filter cord must be plugged into a 3 wire outlet 
  that is protected by a Class A Ground Fault 
 Circuit 

Interrupter.

•  Reset circuit breaker. If circuit breaker trips  
  repeatedly, your electrical system may have a 
  defect. Turn off circuit breaker and call an 
  electrician to correct the problem.
•  Let motor cool down.

•  Adjust the chlorine and pH level. Consult your  
  local swimming pool supply stores.
•  Clean or replace cartridge.
•  Check the cartridge for holes. Replace if 
 damaged.
•  Operate the filter for longer periods.
•  Clean the strainer screen at the inlet.

•  Clear any obstructions in the intake hose by 
  discharging it inside pool wall.
•  Tighten hose clamps, check hoses for damage,  
  check pool water level.
• Replace cartridge. 
•  Clean cartridge more often.
•  Install the nozzle at the upper position of the  
  pool inlet, and the strainer at the lower position  
  of the pool outlet.
•  Make sure the pool inlet air adaptor is 
  connected to the pool inlet upper fitting.

•  Fill pool to correct water level.
•  Clean strainer screens at pool inlet.
•  Tighten hose clamps, check hose for damage.
•  Clear any sticks or leaves in the intake hose.
•  Open the release valve at top of pump.

•  Remove cover & check for O-ring.
•  Tighten cover or valve (Manually).

•  Tighten or reinstall hose clamps.
•  Put the o-ring back into the groove.
•  Replace a new hose.

•  Open air release valve, lift and lower the inlet  
  hose until water starts to flow out of air release  
  valve, close air release valve.

•  Tighten or reinstall hose clamps.
•  Tighten air jet valve and make sure it’s 
 facing 

up.

•  Plug in the pump and run for few seconds, then  
  unplug, repeat 3 times.
•  Remove air jet valve, flush dirt out with water  
  and replace valve back.
•  Replace a new air jet valve.
 

FILTER MOTOR 
FAILS TO START

FILTER DOESN’T 
CLEAN POOL

FILTER DOESN’T 
PUMP WATER OR 
FLOW IS VERY SLOW

PUMP DOESN’T 
WORK

TOP COVER  
LEAKING

HOSE LEAKING

AIR LOCK

POOL INLET AIR 
ADAPTOR / AIR JET 
VALVE LEAKING

•  The motor is not plugged in.
•  The GFCI circuit breaker is tripped.
•  Motor too hot and overload  

 

  protection is shut off.

•  Improper chlorine or pH levels.
•  Filter cartridge is dirty.
• Damaged cartridge.
•  Excessively dirty pool.
•  The strainer screen is 
  restricting the water flow.

•  Clogged inlet or discharge.
•  An air leak on the intake line.
•  Scale or buildup on cartridge.
•  Excessively dirty pool.
•  Dirty filter cartridge.
•  Nozzle and strainer connection are  
 reversed.
•  Pool inlet air adaptor connected to 
  the wrong fitting.

•  Low water level.
•  Strainer screen plugged up.
•  An air leak on the intake hose.
•  Faulty motor or the impeller is  

 

 jammed.
•  An air lock inside the cartridge    
 chamber.

• O-ring missing.
•  Cover or air release valve are not  
   tight.

•  Hose clamps are not well-fitted.
•  Hose o-ring dislodged when
  connecting the hose.
• Hose broken.

•  There’s air trapped in the pump    
  housing and inlet hose.

•  Hose clamps are not well-fitted.
•  Air jet valve is not tight and 
 facing 

 

up.

•  Air jet valve internal seal blocked.
•  Air jet valve internal seal dirty.
•  Air jet valve broken.
  

TROUBLE

CAUSE

SOLUTION

Summary of Contents for Krystal Clear 603

Page 1: ...missing parts call us toll free for U S and Canadian Residents 1 800 234 6839 Monday through Friday 8 30am to 5 00pm Pacific Time Don t forget to try these other fine Intex products Pools Pool Accessories Inflatable Pools and In Home Toys Airbeds and Boats available at fine retailers or visit our website listed below Due to a policy of continuous product improvement Intex reserves the right to cha...

Page 2: ...5 X 10 3 PANTONE 295U 06 15 2016 Page 2 Warnings 3 Parts Reference 4 Setup Instructions 5 6 Maintenance 6 Pool Care and Chemicals 7 Long Term Storage 7 Troubleshooting Guide 8 Common Pool Problems 9 General Aquatic Safety 10 Limited Warranty 11 TABLE OF CONTENTS CAN ICES 3 B NMB 3 B ...

Page 3: ...ilities Children must stay away from this product and electrical cord s Assembly and disassembly by adults only Always unplug this product from the electrical outlet before removing cleaning servicing or making any adjustment to the product Do not bury the electrical cord Locate the cord where it will not be damaged by lawn mowers hedge trimmers and other equipment To reduce the risk of electric s...

Page 4: ... When ordering parts be sure to quote the model number and part numbers No tools are required for the assembly REF NO DESCRIPTION QTY SPARE PART NO 1 AIR RELEASE VALVE 1 10460 2 VALVE O RING 1 10264 3 FILTER HOUSING COVER 1 11868 4 COVER SEAL 1 10325 5 FILTER CARTRIDGE 29000 1 6 HOSE SEAL 2 10134 7 HOSE CLAMP 4 11489 8 HOSE 2 10116 9 STRAINER CONNECTOR 1 11070 10 POOL INLET JET NOZZLE 1 12364 11 S...

Page 5: ...n marked 5 Connect the second hose to the pool inlet air adaptor 15 and to the lower pump connection Make sure all the hose clamps 7 are tight NOTE Make sure the air jet valve 14 is securely tighten onto the pool inlet air adaptor 15 and facing up 6 In a counter clockwise motion unscrew the threaded filter housing collar 12 from the filter housing Grasp and remove the housing cover 3 Check to see ...

Page 6: ...e strainer connectors 3 In a counter clockwise motion remove the filter housing collar 12 and threaded cover 3 Be careful not to lose the cover seal 4 4 Remove filter cartridge 5 to clean it The filter may be cleaned from the spray from a water hose 5 Use judgement as to whether cartridge needs to be replaced 6 Return cartridge to filtering position 7 Return the seal 4 and threaded cover 3 to thei...

Page 7: ...may grow through the liner Filter run time depends on pool size weather and usage level Experiment with various run times so as to produce clean clear water CAUTION Concentrated chlorine solutions may damage the pool liner Always follow the chemical manufacturer s directions and the health and hazard warnings 1 Before emptying your pool for long term storage or relocation be sure the water is dire...

Page 8: ...en air release valve lift and lower the inlet hose until water starts to flow out of air release valve close air release valve Tighten or reinstall hose clamps Tighten air jet valve and make sure it s facing up Plug in the pump and run for few seconds then unplug repeat 3 times Remove air jet valve flush dirt out with water and replace valve back Replace a new air jet valve FILTER MOTOR FAILS TO S...

Page 9: ... Rip or hole in pool liner or hoses The drain valves are loose Heavy use getting in and out of pool Pool too close to trees Super chlorinate with shock treatment Correct pH to your pool store s recommended level Vacuum pool bottom Maintain proper chlorine level Adjust pH level to the recommended level Run filter until water is clear Clean cartridge frequently Correct the pH level Check with your p...

Page 10: ...ompetent adult should be appointed as a lifeguard or water watcher especially when children are in and around the pool Learn to swim Take the time to learn CPR and first aid Instruct anyone who is supervising pool users about potential pool hazards and about the use of protective devices such as locked doors barriers etc Instruct all pool users including children what to do in case of an emergency...

Page 11: ...tes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be subject to the rules and regulations set forth by the Federal Trade Commission F T C IMPLIED WARRANTIES ARE LIMITED ...

Reviews: