Intertec Data Systems CP VARITHERM DPA HI Operating Instructions Manual Download Page 4

www.intertec.info

Operating Instructions CP VARITHERM DPA HI

Page 4 / 8

HOM161029899Ien-6

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   info@intertec.info

 CAUTION

Risk of burns from a hot surface

Attainable highest temperatures:

- Max. 160°C with T3 heating systems

- Max. 100°C with T4 heating systems

- Max. 70°C with T5 heating systems

- Max. 50°C with T6 heating systems

Do not touch device during operation! Before working on
the device, allow it to cool down first.

5

Installation accessories

The following are included in the scope of delivery:

Piece

Description

1

Heating unit

2

Angle bracket made of flat steel

1

Packet of screws containing the following:

4

M 6x12 hexagon bolts

2

T-head bolt type 28/15, M 6x15

2

M6 flat hex nuts

2

Washer shape A 6.4

4

Lock washers shape J 6.4

1

M 6x25 threaded rod shape A

If  one  of  the  components  listed  here  is  not  included  in
the  scope  of  delivery,  then  please  contact  the
manufacturer.

6

Technical Data

Protection class

IP66/IP68 1bar/30min

Rated voltage

max. 250 V AC

Permitted operating voltage

max. 275 V AC

Rated current (in

compliance with VDE 0298)

max. 10 A

Ambient temperature

- 60 to + 60°C

Max. permitted operating

temperature

- 60 to + 180°C

Switching capacity of fault

alarm (AM)

10 A / 275 V AC

Connecting cable

Silicone hose cable,

notch- and oil resistant, 3

x 1,5 mm² Ø8,8 mm

Connecting cable AM

Silicone hose cable,

notch- and oil resistant, 5

x 1,0 mm² Ø8,5 mm

Material

Seawater-proof

aluminium, black

anodized

Mean Time Before Failure

50.000 h

Storage temperature

- 60 to + 80°C

Connecting cable HI

Silicone hose cable,

notch- and oil resistant, 2

x 0,62 mm² and 3 x 1,35

mm², Ø10,2 mm

Special  voltages  with  corresponding  power  adjustment
and component selection are possible.

Profile type "P" Length x

Width x Height

220 x 213 x 120

mm

Profile type "P" Length x

Width x Height

220 x 213 x 100

mm

Profile type "P" Length x

Width x Height

220 x 213 x 80

mm

Profile type "P" Length x

Width x Height

220 x 213 x 60

mm

Profile type "P" Length x

Width x Height

220 x 213 x 40

mm

Profile type "P" Height x

Width x Depth

213 x 220 x 100

mm

Profile type "P" Height x

Width x Depth

213 x 220 x 80 

mm

Profile type "P" Height x

Width x Depth

213 x 220 x 60

mm

Profile type "P" Height x

Width x Depth

213 x 220 x 40

mm

 INFO

You will find the precise technical data for your
instrument on the label.

Summary of Contents for CP VARITHERM DPA HI

Page 1: ...Operating Instructions CP VARITHERM DPA HI HOM161029899Ien 6 17 12 2020...

Page 2: ...contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 5 8 Connection 5 9 Commissi...

Page 3: ...lytical instruments The temperature controller TC connected to the electrical heater has a temperature sensor in the heating coil serving as a temperature limiter EC type examination certificates PTB...

Page 4: ...ge max 275 V AC Rated current in compliance with VDE 0298 max 10 A Ambient temperature 60 to 60 C Max permitted operating temperature 60 to 180 C Switching capacity of fault alarm AM 10 A 275 V AC Con...

Page 5: ...licable requirements of EN 60079 14 must be complied with Additional installation material such as rails or panels and also junction boxes are not included in the standard scope of delivery see Instal...

Page 6: ...eater overheating The heating circuit is permanently disconnected by a temperature melt fuse which can t be reset if these installation instructions are not adhered to 10 Maintenance The design of the...

Page 7: ...n of conformity The manufacturer INTERTEC Hess GmbH Raffineriestrasse 8 93333 Neustadt Donau Germany hereby declares in sole responsibility that the product Product Type designation CP VARITHERM compl...

Page 8: ...8 93333 Neustadt Donau Germany 49 9445 9532 0 info intertec info These instructions do not claim to take all designs options or changes into consideration even in association with installation operat...

Reviews: