+49 9445 9532-0 · [email protected]
CAUTION
Risk of burns from a hot surface
Attainable highest temperatures:
- Max. 160°C with T3 heating systems
- Max. 100°C with T4 heating systems
- Max. 70°C with T5 heating systems
- Max. 50°C with T6 heating systems
Do not touch device during operation! Before working on
the device, allow it to cool down first.
5
Installation accessories
The following are included in the scope of delivery:
For heating with profile depth "N":
Piece
Description
1
Heating unit
1
Angle bracket made of flat steel
1
Packet of screws containing the following:
2
M 6x12 hexagon bolts
1
T-head bolt type 28/15, M 6x15
2
M6 flat square nut
1
Washer shape A 6.4
2
Lock washers shape I 6.4
1
M6 hex nut
For heating with profile depth "P":
Piece
Description
1
Heating unit
2
Angle bracket made of flat steel
1
Packet of screws containing the following:
4
M 6x12 hexagon bolts
2
T-head bolt type 28/15, M 6x15
4
M6 flat square nut
2
Washer shape A 6.4
4
Lock washers shape I 6.4
2
M6 hex nut
If one of the components listed here is not included in
the scope of delivery, then please contact the manufac-
turer.
6
Technical Data
Protection class
IP66/IP68 1bar/30min
Rated voltage
max. 250 V AC
Permitted operating voltage
max. 275 V AC
Rated current (in compli-
ance with VDE 0298)
max. 10 A
Ambient temperature
- 60 to + 60 °C
Max. permitted operating
temperature
- 60 to + 180 °C
Switching capacity of fault
alarm (AM)
10 A / 275 V AC
Connecting cable
Silicone hose cable, notch-
and oil resistant, 3 x 1,5
mm² Ø8,8 mm
Connecting cable AM
Silicone hose cable, notch-
and oil resistant, 5 x 1,0
mm² Ø8,5 mm
Material
Seawater-proof aluminium,
black anodized
Special voltages with corresponding power adjustment
and component selection are possible.
Profile type "N" Height x
Width x Depth
155 x 80 x 80
mm
Profile type "P" Height x
Width x Depth
225 x 80 x 80
mm
INFO
You will find the precise technical data for your in-
strument on the label.
Temperature class
Rated voltage / Operating voltage
High temperature version
Rated output
Illustration 1:
Example: CP MULTITHERM DPA 200 T3 HI label
7
Installation