background image

www.intertec.info

Operating Instructions CP MULTITHERM D.A HI

HOM161009163Ien-1

Page 4 / 8

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

 CAUTION

Risk of burns from a hot surface

Attainable highest temperatures:

- Max. 160°C with T3 heating systems

- Max. 100°C with T4 heating systems

- Max. 70°C with T5 heating systems

- Max. 50°C with T6 heating systems

Do not touch device during operation! Before working on
the device, allow it to cool down first.

5

Installation accessories

The following are included in the scope of delivery:

For heating with profile depth "N":

Piece

Description

1

Heating unit

1

Angle bracket made of flat steel

1

Packet of screws containing the following:

2

M 6x12 hexagon bolts

1

T-head bolt type 28/15, M 6x15

2

M6 flat square nut

1

Washer shape A 6.4

2

Lock washers shape I 6.4

1

M6 hex nut

For heating with profile depth "P":

Piece

Description

1

Heating unit

2

Angle bracket made of flat steel

1

Packet of screws containing the following:

4

M 6x12 hexagon bolts

2

T-head bolt type 28/15, M 6x15

4

M6 flat square nut

2

Washer shape A 6.4

4

Lock washers shape I 6.4

2

M6 hex nut

If  one  of  the  components  listed  here  is  not  included  in
the scope of delivery, then please contact the manufac-
turer.

6

Technical Data

Protection class

IP66/IP68 1bar/30min

Rated voltage

max. 250 V AC

Permitted operating voltage

max. 275 V AC

Rated current (in compli-

ance with VDE 0298)

max. 10 A

Ambient temperature

- 60 to + 60 °C

Max. permitted operating

temperature

- 60 to + 180 °C

Switching capacity of fault

alarm (AM)

10 A / 275 V AC

Connecting cable

Silicone hose cable, notch-

and oil resistant, 3 x 1,5

mm² Ø8,8 mm

Connecting cable AM

Silicone hose cable, notch-

and oil resistant, 5 x 1,0

mm² Ø8,5 mm

Material

Seawater-proof aluminium,

black anodized

Special  voltages  with  corresponding  power  adjustment
and component selection are possible.

Profile type "N" Height x

Width x Depth

155 x 80 x 80

mm

Profile type "P" Height x

Width x Depth

225 x 80 x 80

mm

 INFO

You will find the precise technical data for your in-
strument on the label.

Temperature class

Rated voltage / Operating voltage

High temperature version

Rated output

Illustration 1: 

Example: CP MULTITHERM DPA 200 T3 HI label

7

Installation

Summary of Contents for CP MULTITHERM D.A HI

Page 1: ...Operating Instructions CP MULTITHERM D A HI HOM161009163Ien 1 01 06 2017...

Page 2: ...contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissi...

Page 3: ...The SMART HEATER HI SYSTEM is used for demand ing heating tasks in explosive areas to maintain high temperatures in analytical instruments The temperature controller TC connected to the electrical hea...

Page 4: ...2 hexagon bolts 2 T head bolt type 28 15 M 6x15 4 M6 flat square nut 2 Washer shape A 6 4 4 Lock washers shape I 6 4 2 M6 hex nut If one of the components listed here is not included in the scope of d...

Page 5: ...es must be adhered to The connection cable must be permanently installed up to the inlet into the on site junction box taking the per missible bending radius 5 x outer diameter into consid eration In...

Page 6: ...versible damage to the heater and this would mean that the explosion protection can no longer be warranted The illustration may deviate from the heater 1 2 3 4 5 6 7 8 9 10 11 12 13 L N PE NTC RS 485...

Page 7: ...from bracket and remove it 13 Disposal Disassemble the components of the product taking the applicable local labour protection and environmental reg ulations into consideration and make sure that the...

Page 8: ...ir ectly contact INTERTEC Hess GmbH Raffineriestr 8 93333 Neustadt Donau Germany Phone 49 9445 9532 0 e mail info intertec info Website www intertec info Warranty The legally defined warranties and wa...

Reviews: