Intertec Data Systems CP MICROTHERM DBNA Operating Instructions Manual Download Page 4

www.intertec.info

Operating Instructions CP MICROTHERM DBNA

Page 4 / 8

HOM146708235Ien-4

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

NOTICE

NOTE

It is essential to pay attention to this safety advice as you
may otherwise incur material damage.

 INFO

Important notes and useful additional information.

5

Safety information

 CAUTION

Risk of injury at the rib ends

The sharp edges on the heating ribs may cause injury if
handled incorrectly.

 CAUTION

Risk of burns from a hot surface

Attainable highest temperatures:

- Max. 160°C with T3 heating systems

- Max. 100°C with T4 heating systems

- Max. 70°C with T5 heating systems

- Max. 50°C with T6 heating systems

Do not touch device during operation! Before working on
the device, allow it to cool down first.

6

Installation accessories

The following are included in the scope of delivery:

Piece

Description

1

Heating unit

1

Angle bracket made of flat steel

1

Packet of screws containing the following:

2

Hexagon bolts M 6x12

1

T-head bolt type 28/15, M 6x15

2

M6 flat square nut

1

Washer shape A 6.4

2

Lock washers shape J 6.4

1

M6 hex nut

If  one  of  the  components  listed  here  is  not  included  in
the scope of delivery, then please contact the manufac-
turer.

7

Technical Data

Protection class

IP66/IP68 1bar/30min

Rated voltage

max. 250 V AC

Permitted operating voltage

max. 275 V AC

Rated current (in compli-

ance with VDE 0298)

max. 10 A

Ambient temperature

- 60 to + 60°C

Max. permitted operating

temperature

- 60 to + 180°C

Switching capacity of fault

alarm (AM)

10 A / 275 V AC

Connecting cable

Silicone hose cable,

notch- and oil resistant, 3

x 1,5 mm² Ø8,8 mm

Connecting cable AM

Silicone hose cable,

notch- and oil resistant, 5

x 1,0 mm² Ø8,5 mm

Material

Seawater-proof alu-

minium, black anodized

Mean Time Before Failure

50.000 h

Storage temperature

- 60 to + 80°C

Special  voltages  with  corresponding  power  adjustment
and component selection are possible.

Profile type "N" Height x

Width x Depth

155 x 50 x 50

mm

 INFO

You will find the precise technical data for your in-
strument on the label.

Summary of Contents for CP MICROTHERM DBNA

Page 1: ...Operating Instructions CP MICROTHERM DBNA HOM146708235Ien 4 05 02 2020...

Page 2: ...al 3 2 Use 3 3 Special conditions for safe use 3 4 Explanation of symbols for warnings and signal words 3 5 Safety information 4 6 Installation accessories 4 7 Technical Data 4 8 Installation 5 9 Conn...

Page 3: ...must be protected mechanically 2 If connection is made in the potentially explosive area the connecting lead shall be connected by means of an enclosure that meets the requirements of a type of protec...

Page 4: ...e of flat steel 1 Packet of screws containing the following 2 Hexagon bolts M 6x12 1 T head bolt type 28 15 M 6x15 2 M6 flat square nut 1 Washer shape A 6 4 2 Lock washers shape J 6 4 1 M6 hex nut If...

Page 5: ...be permanently installed up to the inlet into the on site junction box taking the per missible bending radius 5 x outer diameter into consid eration In the dust Ex area the applicable requirements of...

Page 6: ...sed which switches off the supply as soon as the insulation resistance is no greater than 50 per Volt of the rated voltage refer also to ABNT NBR IEC 60079 14 2009 ATTENTION Never remove the adapter c...

Page 7: ...f dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requirements of ABNT NBR IEC 60079 17 and ABNT NBR IEC 60079 19 must be complied with 12...

Page 8: ...79 0 2013 Vers o Corrigida 2 2016 ABNT NBR IEC 60079 1 2016 ABNT NBR IEC 60079 31 2014 ABNT NBR IEC 60529 2005 Vers o Corrigida 2 2011 IEC 61000 6 4 2007 A1 2011 Designation NCC 17 0136 X Ex tb IIIC T...

Reviews: