background image

Application Note 1809

3

AN1809.0

December 5, 2012

3.  The “Choose Install Location” window opens. Click "Next".

4. The “Choose Start Menu Folder” opens. Click “Install”.

5.  The “Completing the Intersil iEvalADC Setup Wizard” window 

opens. Click “Finish”.

6. Setup the hardware as shown in Figure 1. 

7. Windows will automatically detect the new hardware and 

prompt for the appropriate driver via the “Found New 
Hardware Wizard”. Click “No, not this time”, then click "Next".

8. The Software Installation wizard window will open. Click the 

“Install the software automatically (Recommended)” radio 
button, then click "Next".

9. The” Completing the Found New Hardware Wizard” window 

will open. Click “Finish”. (For common issues encountered 
during this process and solutions to these issues, please refer 
to “Appendix B” on page 4).

10. Double click on the iEvalADC shortcut on the desktop to 

launch the application.

FIGURE 5.

FIGURE 6.

FIGURE 7.

 

 

 

FIGURE 8.

FIGURE 9.

FIGURE 10.

 

 

 

Summary of Contents for JESD204B

Page 1: ...ersil iEvalADC is already installed on the machine a new installation may proceed without removing the prior version Features Complete high speed ADC measurement solution 40MSPS to 500MSPS operation Datasheet style live updated display with calculation of critical ADC parameters SNR SFDR SINAD ENOB Harmonics Power Multiple display modes frequency FFT time domain Integrated SPI control for ADC conf...

Page 2: ...on platform the following items are required 1 Intersil ADCMB HSFMCEV1Z motherboard 2 USB cable USB A to USB B 1 25 to 2M long supplied with ADCMB HSFMCEV1Z 3 5V power supply 18 W minimum supplied with ADCMB HSFMCEV1Z 4 Intersil daughter card containing ADC to be tested ordered separately 5 Suitable signal and clock sources see Appendix A on page 4 supplied by user 6 PC with free USB2 0 port logge...

Page 3: ...riate driver via the Found New Hardware Wizard Click No not this time then click Next 8 The Software Installation wizard window will open Click the Install the software automatically Recommended radio button then click Next 9 The Completing the Found New Hardware Wizard window will open Click Finish For common issues encountered during this process and solutions to these issues please refer to App...

Page 4: ...er for both clock and signal sources that does not exceed 200fs is recommended Sample Clock and Input Signal Source Setup Sample clock settings 40MHz to 500MHz sine 10dBm Signal settings 4 5MHz to 250MHz 10dBm to 16dBm depending on analog input attenuation Appendix B Sometimes there are multiple drivers that match the VID PID characteristics of the hardware In those cases a window similar to the f...

Page 5: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Intersil ADCMB HSFMCEV1Z ...

Reviews: