Interroll Module belt conveyor SH 1100
Maintenance and repair
Version 1.0 (06/2022) en
Translation of original operating instructions
67
Replacing the return axle
1
3
4
2
1
1
Torx screw
3
Cover of return axle
2
Side frame
4
Return axle
DANGER
Danger to life from electrocution and crushing
Installation and maintenance tasks on 400-V conveyor systems while they are in operation can
cause life-threatening electrocution and serious crushing.
4
Power down the entire conveyor module and ensure that it cannot be started accidentally.
Fasten screws with a tightening torque of 19 Nm.
Requirement:
R
The module is shut down.
4
Remove cover of the return axle to be replaced,
see "Removing/installing cover plates at
.
4
Unscrew the screws (1) and remove return axle (4).
4
Properly dispose of the old return axle.
4
Fasten the new return axle (4) with screws (1) in the side frame (2).
4
Install the cover of the return axle in reverse order.