Interroll Module belt conveyor SH 1100
Maintenance and repair
64
Version 1.0 (06/2022) en
Translation of original operating instructions
Removing/installing drum
motor (center drive)
2
1
4
9
11
10
10
8
3
8
7
7
2
3
5
6
6
5
1
4
Center drive station
1
Serrated flange bolt
7
Countersunk screw
2
Washer
8
Screw
3
Top clamping piece
9
Drive station
4
Bottom clamping piece
10 Locking plate
5
Washer (small)
11 Drum motor
6
Nut
DANGER
Danger to life from electrocution and crushing
Installation and maintenance tasks on 400-V conveyor systems while they are in operation can
cause life-threatening electrocution and serious crushing.
4
Power down the entire conveyor module and ensure that it cannot be started accidentally.
CAUTION
Risk of injury when lifting heavy loads
4
Use a tool or a second person for steps directly involving the motor.