background image

106

107

Material Specification p 222    Refer to the Planning Section from p 168 onwards for help with planning and design             

Technical Data

Electrical data

 

Rated voltage

24 V DC

Temporarily permissible voltage range

18 to 26 V DC

Permissible voltage undulation

3 %, recommended: < 1 %

Rated current

2.0 A

Max. start-up current

5.0 A

Fuse

present, non-replaceable

Protection rate

IP20

Ambient conditions

 

Ambient temperature in operation

0 to +40 °C

Ambient temperature during transport and storage -20 to +75 °C
Max. temperature change

1 % in 3 h; 2 cycles in compliance with IEC 60068-2-14

Max. air humidity

90 %, non-condensing

Cable cross-sections

 

Power Supply

Fine-wired, 1.5 mm² (AWG 16)

Inputs / Outputs (I/O)

Fine-wired, 0.08 to 0.5 mm² (AWG 28 to 20)

The effective current in the application depends on the conveyor weight, conveyor speed and number of cycles.

Reference number: 89RC

Product Description

The ZoneControl is the single zone control for the RollerDrive EC310. The ZoneControl can be used to create 
stand-alone, zero pressure accumulation conveyors which require no higher-order control. Additional functions and 
communication to upstream and downstream conveyors can be provided via digital inputs and outputs (I/O‘s). No 
DriveControls are needed to set up a conveyor as the ZoneControls include their functions.

The I/O‘s and voltage supply is provided by a simple switching wire.

Communications cable: Conventional Cat-5 cable (IT ethernet cable).

The configuration of the ZoneControl can simply be handled by DIP switches. Two versions of conveyor logic are 
available: individual or block pull-off.

•  Logic for zero pressure accumulation conveying (incl. initialisation)
•  Communication with upstream and downstream zones via peer-to-peer connection
•  Speed adjustment

 

- DIP switch (per accumulation zone)

 

- External analogue signal (for the entire conveyor system)

•  Adjustment of the RollerDrive‘s direction of rotation 

 

- DIP switch

 

- External digital signal

•  LED status indicator
•  Zone sensor connection
•  Start sensor connection
•  NPN or PNP switching logic
•  Switching a second RollerDrive, status reading, starting and stopping of individual zones via I/O‘s
•  Empty running, error signalling of all connected zones via I/O‘s
•  All signals relate to mass of voltage supply 

Properties

Design  

information

Configuration

Functions

ZoneControl

DriveControl

ZoneControl

The accumulation conveyor logic for RollerDrive EC310

DriveControls Overview p 100 

RollerDrive EC310 p 88 

RollerDrive EC310 IP66 p 96

Reviews: