![Interroll RollerDrive EC200 User Manual Download Page 14](http://html1.mh-extra.com/html/interroll/rollerdrive-ec200/rollerdrive-ec200_user-manual_2080331014.webp)
12
Version 1.0 (11/2007) en
Original language
Product information
RollerDrive EC200
Speed settings
If you do not use the recommended DriveControl (
), you may change the speed of the RollerDrive
EC200 by altering the voltage on pin 5 of the motor plug.
Input voltage of Pin 5 at motor plug is not polarity-
proof
Damage to the RollerDrive
¾
Ensure the correct polarity.
$QDORJYROWDJHVHWWLQJRQSLQRIPRWRUSOXJ>9'&@
6SHHG3HUFHQWDJH>@
Hint
In the hatched area the RollerDrive does not run within the specified tolerance of
± 5 %.
Rotary switch
speed setting at
DriveControl
Voltage setting
on pin 5
[VDC]
Speed of transport [m/s (ft/min)] ± 5 %
Gear ratio
12:1
Gear ratio
16:1
Gear ratio
36:1
Gear ratio
48:1
Gear ratio
64:1
0/8
5 to 24
0.98 (192.7)
0.74 (145.6)
0.33 (64.2)
0.25 (49.2)
0.18 (36.1)
1/9
0.98 (192.7)
0.74 (145.6)
0.33 (64.2)
0.25 (49.2)
0.18 (36.1)
2/A
4
0.75 (147.2)
0.56 (110.4)
0.25 (49.1)
0.19 (36.8)
0.14 (27.6)
3/B
3.75
0.56 (110.4)
0.42 (82.8)
0.19 (36.8)
0.14 (27.6)
0.11 (20.7)
4/C
3.30
0.41 (80.1)
0.31 (60.1)
0.14 (26.7)
0.10 (20.0)
0.08 (15.0)
5/D
2.93
0.30 (58.5)
0.22 (43.8)
0.10 (19.5)
0.07 (14.6)
0.06 (11.0)
6/E
2.68
0.21 (41.1)
0.16 (30.9)
0.07 (13.7)
0.05 (10.3)
0.04 (7.7)
7/F
2.44
0.14 (28.1)
0.11 (21.1)
0.05 (9.4)
0.04 (7.0)
0.03 (5.3)