Initial startup and operation
30
Version 2 (02/2020) en
Translation of original operating instructions
Reset to factory setting
4
Select
Configuration > Set Factory Defaults
in the menu.
ð
All settings are returned to the settings at delivery.
Acknowledging an error
4
Select
Configuration > Reset Pallet Control
in the menu.
ð
When the cause of the fault has been removed, the Pallet Control returns to an error-free
state.
Configuration with the
magnetic sensor
The following functions can be executed using the magnetic sensor and a magnet:
• Restart and reset error
• Change the direction of rotation of the motor
• Set switch-off ramps in 3 steps
• Reset Pallet Control to factory settings
IEC
/
EN
60
94
7
IP54
3x400
VA
C /
3A
,
24
VD
C /
2A
In:
ww
w.
int
err
oll
.co
m
Ger
many
–
Hü
ck
elh
ov
en
41
83
6
Gm
bH
Tro
mm
elm
ot
or
en
Int
err
oll
36
/2
01
7
00
00
01
23
4
11
12
82
7
2
1
1
Magnetic key
2
Magnetic sensor
Operating the magnetic sensor requires a magnetic key (1), which is available as an accessory.
The magnetic sensor (2) is located on the circuit board, roughly centered between the
Error
LED
and the
Modus Hold 1
LED.
By default, the magnetic sensor is deactivated and must be turned on in the Pallet Control
Configurator.
Requirement:
R
Neither motor is running.
4
Select
Configuration > Enable magnetic sensor
in the menu.
Pallet Control Configurator is turned on.
4
Hold the magnet to the magnetic sensor for longer than 2 seconds.
Configuration starts.
4
Navigate through the menu and change the settings by holding the magnet to the sensor for
shorter or longer periods of time.