Version 2.0 (12/2019) Online
Translation of the original operating manual
27 von 38
Assembly and installation
5.4
Electrical installation
Connect the control plug with the DriveControl or alternative controller.
If necessary, set the DIP switches according to requirements (see „DIP switches”, page 19).
Insert the plug of the RollerDrive so that with the the „RD” labeling can be read and the „EC310” labeling is to the
rear, i.e. cannot be read.
5.5
Eingänge und Ausgänge
RollerDrive connection: 8 mm snap-in, 5-pin, pin location in accordance with DIN EN 61076-2
1 +24 V DC
4 Input error signal
2 Output for direction of rotation
5 Output speed signal
3 Ground
Controller connection
1 +24 V DC
4 Output error signal
2 Input for direction of rotation
5 Input speed signal
3 Ground