10 GENERAL MAINTENANCE
WARNING
Do not carry out any maintenance if the Portable iMilk401 is connected to the mains. Before
performing any maintenance to the Portable iMilk401, disconnect the machine from the
mains.
The only daily maintenance that must be performed with the device connected to the mains is
washing the milking system.
WARNING
Perform maintenance of the Portable iMilk401 positioning it on a solid base (table) and
perform maintenance with the Portable iMilk401 in a milking or washing position.
10.1 Component maintenance
10.1.1 LE30 and CV 30 pulsators
-
It is recommended to clean the filter cartridge every 6 months for correct pulsator and Control Valve
operation. Proceed as follows:
Remove the filter and rinse it with clean water and liquid soap (e.g. dishwashing detergent - ref.
fig. 1).
CAUTION
In very humid and dusty environments, cleaning should be performed every 3 months.
WARNING
It is forbidden to lubricate the filter with oil
-
If water goes into the pulsator (e.g. due to breakage of a liner), cleaning must be carried out
immediately.
Wash the pulsator (see Figure 2) only with lukewarm water, disconnecting the filter cartridge or
filtered air piping. Alternate 5 seconds of water intake and 5 seconds of air intake; if water starts
coming out of the hood, allow only air intake to prevent the water from affecting the electrical
part. Therefore, leave the pulsator operating for approximately 30 minutes to eliminate excess
water.
CAUTION
It is recommended not to wash the pulsator more than once every 6 months, except in case of
sheath breakage.
-
Once a year, check the frequency and the pulsation ratio. Request the intervention of specialised
personnel.
-
After 5000 hours of operation at 60 ppm, it is necessary to carry out a general review of the pulsator.
Request intervention of your dealer.