8.2 Customised programs
iMilk401 enables you to customise 5 milking programs, each one can be set with different parameter sets.
Parameter Description
Default
Unit
Max/min
P1
P3
P5
P7
P9
ST
IM
U
LAT
ION
23
Stimulation
Time
It enables you to set
the stimulation
duration
//
//
//
//
15
Seconds
0 / 250
24
Stimulation
PR
It enables you to set
the frequency during
stimulation
//
//
//
//
120
Puls/min
50/180
25
Stimo Ratio
REAR
It enables you to set
the REAR pulsation
ratio during stimulation
//
//
//
//
30/70
Ratio
25/75
26
Stimo Ratio
F.
It enables you to set
the FRONT pulsation
ratio during stimulation
//
//
//
//
30/70
Ratio
25 / 75
MAIN
M
ILKIN
G
27 Initial Delay
It enables you to set
how much time to wait
to start monitoring the
quantity of milk
90
90
90
90
75
Seconds
0/255
28 Milking PR
It enables you to set
the frequency during
milking
60
60
60
60
60
Puls/min
50 / 180
29
Milking ratio
R
It enables you to set
the REAR pulsation
ratio during milking
60/40 60/40 65/35 65/35 60/40
Ratio
25 / 75
30
Milking ratio
F
It enables you to set
the FRONT pulsation
ratio during milking
60/40 60/40 65/35 60/40 60/40
Ratio
25 / 75
31 Final Delay
If no continuous flow of
milk is detected after
the delay has elapsed,
it will move on to the
DRIP phase or
detachment operations
will start (only for P1)
9
9
9
9
9
Seconds
0 / 255
LE
VE
L
32
Dripping Int
D.
It enables you to set
how long to wait to
start monitoring the
quantity of milk for the
DRIP phase
//
15
15
15
15
Seconds
0 / 255
33 Dripping PR
It enables you to set
the frequency during
the DRIP phase
//
50
50
50
50
Puls/min
50 / 180
34
Dripping
Ratio F
It enables you to set
the REAR pulsation
ratio during the DRIP
phase
//
50/50 50/50 50/50 50/50
Ratio
25 / 75
35
Dripping
Ratio R
It enables you to set
the FRONT pulsation
ratio during the DRIP
phase
//
50/50 50/50 50/50 50/50
Ratio
25 / 75