PORTABLE IMILK401
-
Instruction Manual, Operation and
Maintenance original instructions
5640015_07.17_EN
THIS MANUAL IS THE PROPERTY OF -
InterPuls
S.p.A.
-
ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 35
7.2.3
Diagram of automatic milking (program P1)
7.2.4
Drip
Using programs P3
– P5 – P7 – P9, if the flow of milk remains below the
Min Flow Dripp
until
Final Delay
has elapsed, the DRIP phase will start. During this time, you can set different frequency values and milking
ratio from the main milking (typically 50:50 per 50ppm). If the flow of milk remains below the threshold set in
the
Min Flow Detach
parameter for a minimum duration equivalent to the
Drip Final Delay
, detachments
operations will start. An arrow is displayed on the right side of the screen throughout the drip phase.
Once
VACUUM DELAY
has elapsed,
pulsation is activated and starts to
count the milking time
Once
INITIAL DELAY
has elapsed, the
main milking starts together with
monitoring of the milk
Milking proceeds as usual until the
quantity of monitored milk drops below
the threshold set in the
MIN FLOW
DRIPP.
Then
FINAL DELAY
counting
starts
If sufficient milk is detected again for
MIN FLOW DRIPP
before the
FINAL
DELAY
has elapsed, milking proceeds
as usual
If sufficient milk is
NOT
detected again
from the
MIN FLOW DRIPP
before the
FINAL DELAY
has elapsed,
detachment operations will start
MILKING
MAIN
DRIP FLOW
LEVEL
1 2 3 …
Initial Delay
1 2 3 …
Final
Delay
1 2 3 …
Final
Delay
1 2 3 …
Final
Delay
Detachment
Drip indicator