Setting Port and Clock Modes
168
Interphase Corporation
When this mode is selected, the text message portion of the
Line Test main dialog box displays the following
synchronization results:
Operational Mode
After a test has completed, you must return the port used for
testing to Operational mode so that it can handle incoming and
outgoing communications.
To return the port to Operational mode, select
Operational
mode
on the Port Test Configuration dialog box (shown in
).
Before closing the Line Test utility, you are requested to
restore each port in testing mode to the operational mode.
Clock Modes
In some test configurations (such as
back-to-back
configurations), a port must use the remote card clock to
successfully synchronize on the received signal.
Message
Meaning
No error
The receiving bit sequences completed, and
the port found no errors when comparing
sent and received bit sequences.
X bits in error/sec
The port is comparing received bit
sequences with sent bit sequences.
Each erroneous bit found is added, and the
sum is displayed each second.
Not synchronized
The port is unable to recognize what it sent.
Summary of Contents for ENTIA 5536 DM PRI
Page 34: ...Minimum System Requirements 14 Interphase Corporation...
Page 46: ...Connecting to an MVIP Bus 26 Interphase Corporation...
Page 56: ...Connecting to the Network 36 Interphase Corporation...
Page 90: ...Removing the Drivers 70 Interphase Corporation...
Page 136: ...Verifying COM Ports 116 Interphase Corporation...
Page 172: ...Saving and Editing Frames 152 Interphase Corporation...
Page 182: ...Understanding LoopTest Messages 162 Interphase Corporation...
Page 190: ...Setting Port and Clock Modes 170 Interphase Corporation...
Page 196: ...Interpreting Line Status Indicators 176 Interphase Corporation...
Page 208: ...Procedures 188 Interphase Corporation...
Page 220: ...Europe 200 Interphase Corporation...