RSA 2625-TB RANDOM SEMI-AUTOMATIC CASE SEALER
Setup Procedures
4-5
4.5.2 Air Connection
The regulator has a male "quick disconnect" adaptor. Connect clean dry compressed air to this adapter. The
RSA2625-TB Random Semi-Automatic Case Sealer requires a minimum of 3 C.F.M. at
75 PSI
maximum.
To regulate the air pressure, pull on the green knob located on the side of the machine. Turn the knob
clockwise for more pressure and counter clockwise for less. When the air pressure is at
75 PSI
, push back
down on the button until a "click" is felt. The threading size is 3/8 NPT (refer to Figure 4-5).
Figure 4-5 Air Regulator
4.5.3 Pneumatic Adjustment
The main air filter/regulator controls the air pressure going inside the machine. It also controls the air pressure
inside the cylinders that raise the Top Belt Drive Assembly and open the infeed guides.
The recommended
pressure setting for the main air filter/regulator is between 60 and 70 PSI.
The Infeed Guide Pressure is controlled with the pressure regulator located at the infeed end of the machine,
under the left hand Side Cover. By
increasing
the air pressure, you
increase
the centering force of the guides on
the box.
The recommended pressure setting for the Infeed Guide regulator is between 30 and 40 PSI.
The weight of the Top Belt Drive Assembly on the box is controlled by the High Flow Pressure Control located at
the discharge end of the machine, under the left hand Side Cover. This controls the air pressure at the bottom of
the cylinder and counterbalance for the weight of the Top Belt Drive Assembly. Therefore, to
reduce
the weight
applied on the top of the box, you have to
increase
the air pressure.
The recommended pressure setting for
the High Flow Pressure Control is between 35 and 45 PSI.
Summary of Contents for ipg RSA 2625-TB
Page 5: ...Table of Contents RSA 2625 TB RANDOM SEMI AUTOMATIC CASE SEALER ii ...
Page 6: ...Table of Contents RSA 2625 TB RANDOM SEMI AUTOMATIC CASE SEALER ii ...
Page 16: ...RSA 2625 TB RANDOM SEMI AUTOMATIC CASE SEALER Important Safeguards 2 6 Notes ...
Page 20: ...RSA 2625 TB RANDOM SEMI AUTOMATIC CASE SEALER Setup Procedures 4 1 Notes ...
Page 29: ...RSA 2625 TB RANDOM SEMI AUTOMATIC CASE SEALER Setup Procedures 4 9 Notes ...
Page 32: ...RSA 2625 TB RANDOM SEMI AUTOMATIC CASE SEALER Operating Instructions 5 1 ...
Page 35: ...RSA2625 TB ILLUSTRATED PARTS LIST 7 2 7 1 UMXXX RSA2625 TB TOP LEVEL ASSEMBLY ...
Page 36: ...RSA2625 TB ILLUSTRATED PARTS LIST 7 3 7 2 USM0882 BASE ASSEMBLY ...
Page 37: ...RSA2625 TB ILLUSTRATED PARTS LIST 7 4 7 3 USM0873 COLUMN ASSEMBLY ...
Page 38: ...ILLUSTRATED PARTS LIST RSA2625 TB 7 5 ...
Page 39: ...RSA2625 TB ILLUSTRATED PARTS LIST 7 6 7 4 USM0879 TOP BELT ASSEMBLY ...
Page 40: ...ILLUSTRATED PARTS LIST RSA2625 TB 7 7 ...
Page 41: ...RSA2625 TB ILLUSTRATED PARTS LIST 7 8 7 5 USM0411 ELECTRIC CONTROL BOX ASSEMBLY ...
Page 42: ...ILLUSTRATED PARTS LIST RSA2625 TB 7 9 ...
Page 43: ...ILLUSTRATED PARTS LIST RSA2625 TB 7 10 7 6 USM0880 BOTTOM DRIVE ASSEMBLY ...
Page 44: ...RSA2625 TB ILLUSTRATED PARTS LIST 7 11 ...
Page 45: ...RSA2625 TB ILLUSTRATED PARTS LIST 7 12 7 7 USM0878 CENTERING MECHANISM ...
Page 46: ...ILLUSTRATED PARTS LIST RSA2625 TB 7 13 ...
Page 47: ...RSA2625 TB ILLUSTRATED PARTS LIST 7 14 7 8 USM0881 PNEUMATIC CONTROL ASSEMBLY ...