Page 8
3. Use a 3/32” drill bit to drill a starter hole through
the hole in the bracket and into the window
sash.
4. Attach window-lock
bracket to window
sash with #10 x ¾”
round-head screw to
secure window in
place.
A.
Window lock bracket (2)
B.
Foam seal
C.
Upper window glass
D.
#10 x 1/2” pan-head Phillips screws (3)
Wall Installation
NOTES:
•
Handle air conditioner gently.
•
Be sure your air conditioner cabinet does not fall out of the opening during installation or removal.
•
The location where the power cord exits the air conditioner should be no more than 4 ft (122cm) from a
grounded 3 prong outlet.
•
Do not block the louvers on the front panel.
•
Do not block the louvers on the outside of the air conditioner.
•
It is the customer’s responsibility and obligation to have this product installed by a qualified technician familiar
with through-the-wall room air conditioner installations.
Option 1 – Wood, metal or plastic molding
When you are using wood, metal or plastic molding,
the wood frame should line up with inside wall as
shown.
Option 2 – Plastered wall with no molding
If the plastered wall is to be flush with the cabinet
and no molding is used, the wood frame must be set
½” (13mm) into the inside wall.