background image

 

Page 6

 
 
 
 
 

 
 
 
 
 
 
 
 

 
Attach side curtains 

1. 

Locate provided bag of screws 

2. 

Insert  top  and  then  bottom  of  right-hand  curtain 

housing  in  top  and  bottom  curtain  guides  on  air 
conditioner cabinet. 

 
Back View 
 
 
 
 
 
 
 
 
 
 
 
 
Bottom View 
 
 
 
 
 

 
 
 
 

3. 

Extend  right-hand  curtain  outward  so  you  may 

insert  the  first  screw  through  the  middle  hole  of  the 
curtain. Using #10 x ¼” pan-head Phillips screw, screw 
curtain to middle hole in air conditioner cabinet. 
NOTE:  This  screw  is  required  to  correctly  attach 
curtain (top to bottom) to the air conditioner cabinet. 
 
 
 
 
 
 
 
 
 

4. 

While  the  right  hand  curtain  is  still  extended, 

insert  #10  x  ¼”  pan-head  Phillips  screws  into  the  top 
and  bottom  slots  of  curtain.  Screw  Curtain  to  the  top 
and bottom holes in air conditioner cabinet. 
NOTE: Some curtains may have 2 slots on  each end. 
You  will  be  able  to  see  a  mounting  hole  through  the 
correct slot. 
5. 

Slide curtain housing into  guides as far  as  it  will 

go. 
6. 

Repeat above steps for left-hand curtain. 

 

Attach Foam Adhesive Seal 
Attach foam adhesive seal along the bottom of the 
curtain bottom channel. 
 
 
 
 
 
 
 
 
 
 
 
 

 

Install Cabinet into Window 

 

Handle air conditioner gently. 

 

Be sure your air conditioner cabinet does not fall 
out of the opening during installation or removal. 

 

The  location  where  the  power  cord  exits  the  air 
conditioner should be no more than 4 ft (122cm) 
from a grounded 3 prong outlet. 

 

Do not block the louvers on the front panel. 

 

Do not block the louvers on the outside of the air 
conditioner. 

 

1.  Center  empty  cabinet  in  window.  Check  that 

lower rail of air conditioner cabinet is behind and 
against  back  side  of  windowsill.  Maintain  a  firm 
hold  on  the  air  conditioner  cabinet.  Lower 
window  sash  to  hold  cabinet  in  place.  Top 
channel must be on inside room of window sash. 

 
 
 
 
 
 
 
 
 
 
 
 
 
2.  Measure  the  distance  between  the  right-hand 

side of the cabinet and the inside  of the window 
channel 

3.  Repeat  for  left  side.  Adjust  the  cabinet  until  the 

distance on each side is the same. 

Summary of Contents for WHP412230R

Page 1: ...INDOW HEAT PUMP USER MANUAL 950 0190revD 02 19 2014 FOR MODELS COOLING CAPACITY HEATING CAPACITY WHP49230R WHP49ZR 9 200 9 500 BTU 11 200 11 600 BTU WHP412230R WHP412ZR 8 100 8 400 BTU 10 000 10 300BT...

Page 2: ...le air conditioner is an environmentally safe and friendly ATTENTION Keep small children away from portable unit Do not modify or otherwise defeat the plug The appliance shall be installed and operate...

Page 3: ...nife Parts Supplied A Foam window sash seal B Window lock brackets 2 C 10 x 1 4 pan head Phillips screws 6 D 10 x 3 8 pan head Phillips screws 3 or 7 E 10 x 3 4 round head screws 6 F 10 x 1 2 pan head...

Page 4: ...ou will need to modify them for other types of windows The air conditioner can be installed without the accordion panel if needed to fit in a narrow window See Window Opening dimensions All supporting...

Page 5: ...e may differ from the ones shown This room air conditioner is equipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current I...

Page 6: ...ditioner on cardboard 5 Remove any packing foam from inside of unit NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is not packing material Window...

Page 7: ...ing into guides as far as it will go 6 Repeat above steps for left hand curtain Attach Foam Adhesive Seal Attach foam adhesive seal along the bottom of the curtain bottom channel Install Cabinet into...

Page 8: ...pe B screws in each support CAUTION Do not install this air conditioner in a window if the bolts do not contact the window sill Attach Side Curtains to Window Frame 1 Pull left hand curtain out until...

Page 9: ...rd exits the air conditioner should be no more than 4 ft 122cm from a grounded 3 prong outlet Do not block the louvers on the front panel Do not block the louvers on the outside of the air conditioner...

Page 10: ...on both sides of cabinet 3 Insert front tabs of front panel into top of cabinet and swing front into place 4 Attach bottom front of panel with front panel screws NOTE For wall installations if needed...

Page 11: ...r heating Use the Temperature Increase Decrease pads to set the desired temperature between 64 F and 86 F in 1 F increments The display will indicate the set temperature in the heat mode Your window u...

Page 12: ...air conditioner off wait at least 3 minutes before turning it back on This prevents the air conditioner from blowing a fuse or tripping a circuit breaker Press buttons Increase and Decrease at the sam...

Page 13: ...ll be activated and the compressor will turn off 7 Delay Button Used to select the amount of time before the air conditioner turns off when on or the amount of time before the air conditioner turns on...

Page 14: ...the sound of water you hear during normal operation The water quickly evaporates on this warm surface and improves the efficiency of your air conditioner In normal conditions the unit can evaporate th...

Page 15: ...detergent Do not wash air filter in the dishwasher or use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency Cleaning the Front Panel 1 Turn off the air cond...

Page 16: ...st 3 minutes after turning the unit off before trying to restart the air conditioner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can trip Rese...

Page 17: ...conditioner to cool off a very hot room Windows or doors to the outside are open Close all windows and doors The temperature set point or Thermostat control is not at a cool enough setting Adjust the...

Page 18: ...0P Power Cord Rating amps 18A 18A Power Cord Length Inches 59 59 Minimum Circuit Breaker Size amps 20A 20A Minimum Circuit Capacity amps 20A 20A Refrigerant Charge R410a oz 24 69 28 22 Max dbA Level I...

Page 19: ...provides free replacement of defective parts only Labor is not covered under this warranty Replacement as a result of normal wear and tear is not covered under this warranty Additional claims are excl...

Reviews: