background image

 

Page 18 

WARRANTY 

International  Refrigeration  Products  warrants  that  the  product  supplied  is  free  from  defects  in 
material  and  workmanship.  This  warranty  is  valid  as  long  as  this  product  is  properly  handled, 
installed,  operated  and  serviced  in  accordance  with  the  Installation  and  Operating  Instructions 
shipped  with  this  unit,  and the  warranty  card  is completed  and  mailed  no  later than  30  days  after 
date  of  purchase.  All  warranty  claims  must  be  made  within  one  (1)  year  (five  (5)  years  for 
compressor)  from  date  of  purchase  (unless  national  regulations  require  a  longer  registration 
period). 
 
This warranty provides free replacement of defective parts only. Labor is not covered under this 
warranty.  Replacement  as  a  result  of  normal  wear  and  tear  is  not  covered  under  this 
warranty. 
 
Additional claims are excluded, unless required by national regulations. International Refrigeration 
Products  Inc.  is  not  responsible  for  incidental,  consequential,  direct,  or  indirect  damages,  or 
expenses  relating  to the  use  of,  or  the  inability  to  use  the  product for  any  purpose.  Other  implied 
warranties are excluded. 
 
This constitutes International  Refrigeration Products’ warranty obligation  and replaces any  and all 
prior warranties for this product. 
 
International Refrigeration Products Inc 
1035 Wheeler Way 
Langhorne, PA 19047 
Service - Tel: 215-750-9876 Fax: 215-750-1169 

Hours: 8:00 AM to 4:30 PM EST 

Website: www.irproducts.biz 

 
 
 

Summary of Contents for WHP412230R

Page 1: ...INDOW HEAT PUMP USER MANUAL 950 0190revD 02 19 2014 FOR MODELS COOLING CAPACITY HEATING CAPACITY WHP49230R WHP49ZR 9 200 9 500 BTU 11 200 11 600 BTU WHP412230R WHP412ZR 8 100 8 400 BTU 10 000 10 300BT...

Page 2: ...le air conditioner is an environmentally safe and friendly ATTENTION Keep small children away from portable unit Do not modify or otherwise defeat the plug The appliance shall be installed and operate...

Page 3: ...nife Parts Supplied A Foam window sash seal B Window lock brackets 2 C 10 x 1 4 pan head Phillips screws 6 D 10 x 3 8 pan head Phillips screws 3 or 7 E 10 x 3 4 round head screws 6 F 10 x 1 2 pan head...

Page 4: ...ou will need to modify them for other types of windows The air conditioner can be installed without the accordion panel if needed to fit in a narrow window See Window Opening dimensions All supporting...

Page 5: ...e may differ from the ones shown This room air conditioner is equipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current I...

Page 6: ...ditioner on cardboard 5 Remove any packing foam from inside of unit NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is not packing material Window...

Page 7: ...ing into guides as far as it will go 6 Repeat above steps for left hand curtain Attach Foam Adhesive Seal Attach foam adhesive seal along the bottom of the curtain bottom channel Install Cabinet into...

Page 8: ...pe B screws in each support CAUTION Do not install this air conditioner in a window if the bolts do not contact the window sill Attach Side Curtains to Window Frame 1 Pull left hand curtain out until...

Page 9: ...rd exits the air conditioner should be no more than 4 ft 122cm from a grounded 3 prong outlet Do not block the louvers on the front panel Do not block the louvers on the outside of the air conditioner...

Page 10: ...on both sides of cabinet 3 Insert front tabs of front panel into top of cabinet and swing front into place 4 Attach bottom front of panel with front panel screws NOTE For wall installations if needed...

Page 11: ...r heating Use the Temperature Increase Decrease pads to set the desired temperature between 64 F and 86 F in 1 F increments The display will indicate the set temperature in the heat mode Your window u...

Page 12: ...air conditioner off wait at least 3 minutes before turning it back on This prevents the air conditioner from blowing a fuse or tripping a circuit breaker Press buttons Increase and Decrease at the sam...

Page 13: ...ll be activated and the compressor will turn off 7 Delay Button Used to select the amount of time before the air conditioner turns off when on or the amount of time before the air conditioner turns on...

Page 14: ...the sound of water you hear during normal operation The water quickly evaporates on this warm surface and improves the efficiency of your air conditioner In normal conditions the unit can evaporate th...

Page 15: ...detergent Do not wash air filter in the dishwasher or use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency Cleaning the Front Panel 1 Turn off the air cond...

Page 16: ...st 3 minutes after turning the unit off before trying to restart the air conditioner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can trip Rese...

Page 17: ...conditioner to cool off a very hot room Windows or doors to the outside are open Close all windows and doors The temperature set point or Thermostat control is not at a cool enough setting Adjust the...

Page 18: ...0P Power Cord Rating amps 18A 18A Power Cord Length Inches 59 59 Minimum Circuit Breaker Size amps 20A 20A Minimum Circuit Capacity amps 20A 20A Refrigerant Charge R410a oz 24 69 28 22 Max dbA Level I...

Page 19: ...provides free replacement of defective parts only Labor is not covered under this warranty Replacement as a result of normal wear and tear is not covered under this warranty Additional claims are excl...