background image

 

Page 10 

AIR CONDITIONER USE 

----------------------------------------------------------------------------------------------------------------------------------

Cool Mode Feature 
 

 

Use the Cool mode at Low, Med, High or Auto Fan 
Speed 
for cooling. Use the Temperature Increase 
/Decrease
 pads to set the desired temperature between 
64°F and 86°F in 1°F increments.  
 
The display will indicate the set temperature in the cool 
mode. An electronic thermostat is used to maintain the 
room temperature. The compressor will cycle on and off 
to keep the room at the set level of comfort. Set the 
thermostat at a lower number and the indoor air will 
become cooler. Set the thermostat at a higher number 
and the indoor air will become warmer. 
 

NOTE:  
If the air conditioner is off and is then turned on while set 
to a Cool setting or if turned from a fan setting to a Cool 
setting, it may take approximately 3 minutes for the 
compressor to start and cooling to begin.  
Cooling Descriptions  
For Normal Cooling—Select the Cool mode - Low or 
Med fan speed - Select a normal cooling temperature. 
For Maximum Cooling—Select the Cool mode - High 
fan speed - Select a lower set temperature if necessary. 
For Quieter and Nighttime Cooling—Select the Cool 
mode - Low fan - Select a comfortable set temperature. 

----------------------------------------------------------------------------------------------------------------------------------

Heat Mode Feature

 
Use the Heat mode at Low, Med, High or Auto Fan 
Speed 
for heating. Use the Temperature Increase 
/Decrease
 pads to set the desired temperature 
between 64°F and 86°F in 1°F increments.  
 
The display will indicate the set temperature in the heat 
mode. Your window unit is heat pump with auxiliary 
electric heating. Unit will select compressor operation 
or electric heater depending on the difference between 
room temperature and ambient temperature. The heat 
pump and electric heater will not operate at the 
same time.
 

 
NOTE
Do not try to operate your air conditioner in the heating 
ode when outside temperature is above 86°F, the 
inside evaporator coil will freeze up. 
 
When the outdoor temperature is below 55°F the 
electric heat will be activated and the compressor will 
turn off. 
 

 
 

----------------------------------------------------------------------------------------------------------------------------------

Fan Only Mode Feature 

 
Use the Fan Only Mode at Low, Med or High fan speed 
to provide air circulation and filtering without cooling. 
Since fan-only settings do not provide cooling, a Set 
Temperature
 cannot be entered. The room temperature 
will appear in the display. 

 
NOTE: Auto Fan Speed cannot be used when in the Fan 
Only
 Mode. 

----------------------------------------------------------------------------------------------------------------------------------

Energy Saver Mode Feature – Cooling Only 
 

The energy saver mode operates the cooling system 
only. 
ON – The will cycle on and off with the compressor. 
This may result in wider variations of room temperature 
and humidity.   

OFF – The fan operates continuously as the 
compressor cycles on and off. 
NOTE: The fan may continue to run for a short time 
after the compressor cycles off. 

----------------------------------------------------------------------------------------------------------------------------------

Summary of Contents for WHP412230R

Page 1: ...INDOW HEAT PUMP USER MANUAL 950 0190revD 02 19 2014 FOR MODELS COOLING CAPACITY HEATING CAPACITY WHP49230R WHP49ZR 9 200 9 500 BTU 11 200 11 600 BTU WHP412230R WHP412ZR 8 100 8 400 BTU 10 000 10 300BT...

Page 2: ...le air conditioner is an environmentally safe and friendly ATTENTION Keep small children away from portable unit Do not modify or otherwise defeat the plug The appliance shall be installed and operate...

Page 3: ...nife Parts Supplied A Foam window sash seal B Window lock brackets 2 C 10 x 1 4 pan head Phillips screws 6 D 10 x 3 8 pan head Phillips screws 3 or 7 E 10 x 3 4 round head screws 6 F 10 x 1 2 pan head...

Page 4: ...ou will need to modify them for other types of windows The air conditioner can be installed without the accordion panel if needed to fit in a narrow window See Window Opening dimensions All supporting...

Page 5: ...e may differ from the ones shown This room air conditioner is equipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current I...

Page 6: ...ditioner on cardboard 5 Remove any packing foam from inside of unit NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is not packing material Window...

Page 7: ...ing into guides as far as it will go 6 Repeat above steps for left hand curtain Attach Foam Adhesive Seal Attach foam adhesive seal along the bottom of the curtain bottom channel Install Cabinet into...

Page 8: ...pe B screws in each support CAUTION Do not install this air conditioner in a window if the bolts do not contact the window sill Attach Side Curtains to Window Frame 1 Pull left hand curtain out until...

Page 9: ...rd exits the air conditioner should be no more than 4 ft 122cm from a grounded 3 prong outlet Do not block the louvers on the front panel Do not block the louvers on the outside of the air conditioner...

Page 10: ...on both sides of cabinet 3 Insert front tabs of front panel into top of cabinet and swing front into place 4 Attach bottom front of panel with front panel screws NOTE For wall installations if needed...

Page 11: ...r heating Use the Temperature Increase Decrease pads to set the desired temperature between 64 F and 86 F in 1 F increments The display will indicate the set temperature in the heat mode Your window u...

Page 12: ...air conditioner off wait at least 3 minutes before turning it back on This prevents the air conditioner from blowing a fuse or tripping a circuit breaker Press buttons Increase and Decrease at the sam...

Page 13: ...ll be activated and the compressor will turn off 7 Delay Button Used to select the amount of time before the air conditioner turns off when on or the amount of time before the air conditioner turns on...

Page 14: ...the sound of water you hear during normal operation The water quickly evaporates on this warm surface and improves the efficiency of your air conditioner In normal conditions the unit can evaporate th...

Page 15: ...detergent Do not wash air filter in the dishwasher or use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency Cleaning the Front Panel 1 Turn off the air cond...

Page 16: ...st 3 minutes after turning the unit off before trying to restart the air conditioner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can trip Rese...

Page 17: ...conditioner to cool off a very hot room Windows or doors to the outside are open Close all windows and doors The temperature set point or Thermostat control is not at a cool enough setting Adjust the...

Page 18: ...0P Power Cord Rating amps 18A 18A Power Cord Length Inches 59 59 Minimum Circuit Breaker Size amps 20A 20A Minimum Circuit Capacity amps 20A 20A Refrigerant Charge R410a oz 24 69 28 22 Max dbA Level I...

Page 19: ...provides free replacement of defective parts only Labor is not covered under this warranty Replacement as a result of normal wear and tear is not covered under this warranty Additional claims are excl...

Reviews: