INSTALLATION INSTRUCTIONS 

Prepare Your Unit 

 
 
 
 
 
 
Install the Top Mounting Rail. 
 

 

Locate provided bag of screws.  

 

Remove the tape at back side of sponge, 
and then align it at the bottom edge of upper 
rail to attach the sponge to the upper rail. 

 

Use 4 type A screws (See Page 2) to attach 
the top mounting rail to the air conditioner.  

 
 
 
 
 
 
 

 
 
Note: For some models, the top mounting 
rail might be pre-installed to the unit, skip 
this step if it is installed.  
 

 
 
 
 
 
 
 
 
 

 
 
Install the Accordion Panels 
 

 

Hold the accordion panel in one hand and 
gently pull back to free the open end. 

 
 
 
 

 
 
 
 
 
 

 

 

Stick one sealing strip respectively on the 
left side and right side of accordion panel as 
shown below. 

 

Install the left and right accordion panels into 
both sides of the air conditioner respectively.  

 
 
 

 
 
 
 
 
 

 

Slide the panel all the way in and repeat on 
the other side. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

Summary of Contents for WA410YER

Page 1: ...WINDOW AIR CONDITIONER USER MANUAL 950 0270 revA 9 30 2019 FOR MODELS COOLING BTU h WA46YER 6 050 WA48YER 8 000 WA410YER 10 200 WA412YER 12 100...

Page 2: ...rations and usage Please read carefully the sections corresponding to the specific model you have and keep the manual in a safe place for reference The refrigerant used in your window air conditioner...

Page 3: ...Page 2 INSTALLATION REQUIREMENTS Tools and Parts...

Page 4: ...conditioner can be installed without the accordion panel if needed to fit in a narrow window See Window Opening dimensions All supporting parts must be secured to firm wood masonry or metal Follow the...

Page 5: ...l codes and ordinances Power Supply Cord NOTE Your unit s device may differ from the ones shown This room air conditioner is equipped with a power supply cord required by UL This power supply cord con...

Page 6: ...to the air conditioner Note For some models the top mounting rail might be pre installed to the unit skip this step if it is installed Install the Accordion Panels Hold the accordion panel in one han...

Page 7: ...itioner in window Check that lower rail of air conditioner is behind and against back side of window sill Maintain a firm grip on the air conditioner cabinet Lower window sash to hold cabinet in place...

Page 8: ...oom Install the R1 Hardware In order to minimize air leaks and ensure optimal insulation it is necessary to install the included R1 hardware to the side curtain Follow the instructions below After the...

Page 9: ...thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The air conditioner can be controlled by the...

Page 10: ...button After Fan operates for 250 hours this indicator will be delighted Clean the filter when the light is on 5 Delay 1 24 Hrs button Press this button to set the TIMER ON and TIMER OFF The setting i...

Page 11: ...F In timer mode the time will be increased or decreased by 1 hour 7 Display The display will show the following o ENERGY SAVER FAN ONLY COOL show the room temp o TIMER shown the setting timer in the f...

Page 12: ...e controller either move these appliances or consult your local dealer Replacing Batteries The remote control is powered by two AAA alkaline batteries housed in the back of the remote Do not use recha...

Page 13: ...e fan speed The auto Fan can t be set in this mode o Energy Saver In this mode air conditioner operates the Energy Saver mode The energy saver indicator will be on Press Fan Speed button can adjust th...

Page 14: ...nds Air Directional Louvers Normal Sounds When your air conditioner is operating normally you may hear sounds such as o Droplets of water hitting the condenser causing a pinging or clicking sound The...

Page 15: ...dry the filter completely before replacing to ensure maximum efficiency 4 Install the filter Cleaning the Front Panel 1 Turn off the air conditioner 2 Remove the air filter and clean it separately See...

Page 16: ...t least 3 minutes after turning the unit off before trying to restart the air conditioner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can trip...

Page 17: ...to the outside are open Close all windows and doors The Vent control is set to open on some models Push the Vent control to CLOSED for maximum cooling and or heating The temperature set point or Ther...

Page 18: ...840 1000 Plug Type LCDI 5 15P 5 15P 5 15P 5 15P Power Cord Rating amps 10 13 13 15 Power Cord Length ft 6 6 6 6 Refrigerant Charge R410a oz 14 82 16 2 20 46 24 69 Max dbA Level Indoor Outdoor 65 67 6...

Page 19: ...LABOR IS NOT COVERED 2 OUT OF CARTON ISSUES MUST BE REPORTED WITHIN ONE DAY 3 PARTS ARE COVERED FOR 1 YEAR 4 COMPRESSORS ARE COVERED FOR 1 YEAR 5 NORMAL WEAR AND TEAR IS NOT COVERED Additional claims...

Reviews: