background image

 

Page 7 

Install the Support Bracket and

 

Seal the 

Window

 

 

Install the fixe bracket of window at the 
window frame to fix the window. 

NOTE

: To prevent the window sill from splitting, 

drive the 1/8

” pilot holes before driving screws. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Cut the foam top window gasket to the 
window width. 

 

Stuff the foam between the glass and the 
window to prevent air and insects from 
getting into the room. 

 

 
 
 
 
 
 
 
 
 
 
 
 

Install

 

the R1 Hardware

  

In order to minimize air leaks and ensure optimal 
insulation, it is necessary to install the included R1 
hardware to the side curtain. Follow the instructions 
below. 

 

After the unit is installed to the window, measure 
the inner width (dimension 

“L” as below shown) of 

the side curtain as shown. 

 

 

 

Remark a line on the provided R1 insulation panel 
according to the measured width, then cut the R1 
insulation panel along the line. 

 

 

Slide the R1 insulation panel into the side curtain, 
the side with pattern should facing the indoor side. 

 

Repeat on the other side. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for WA410YER

Page 1: ...WINDOW AIR CONDITIONER USER MANUAL 950 0270 revA 9 30 2019 FOR MODELS COOLING BTU h WA46YER 6 050 WA48YER 8 000 WA410YER 10 200 WA412YER 12 100...

Page 2: ...rations and usage Please read carefully the sections corresponding to the specific model you have and keep the manual in a safe place for reference The refrigerant used in your window air conditioner...

Page 3: ...Page 2 INSTALLATION REQUIREMENTS Tools and Parts...

Page 4: ...conditioner can be installed without the accordion panel if needed to fit in a narrow window See Window Opening dimensions All supporting parts must be secured to firm wood masonry or metal Follow the...

Page 5: ...l codes and ordinances Power Supply Cord NOTE Your unit s device may differ from the ones shown This room air conditioner is equipped with a power supply cord required by UL This power supply cord con...

Page 6: ...to the air conditioner Note For some models the top mounting rail might be pre installed to the unit skip this step if it is installed Install the Accordion Panels Hold the accordion panel in one han...

Page 7: ...itioner in window Check that lower rail of air conditioner is behind and against back side of window sill Maintain a firm grip on the air conditioner cabinet Lower window sash to hold cabinet in place...

Page 8: ...oom Install the R1 Hardware In order to minimize air leaks and ensure optimal insulation it is necessary to install the included R1 hardware to the side curtain Follow the instructions below After the...

Page 9: ...thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The air conditioner can be controlled by the...

Page 10: ...button After Fan operates for 250 hours this indicator will be delighted Clean the filter when the light is on 5 Delay 1 24 Hrs button Press this button to set the TIMER ON and TIMER OFF The setting i...

Page 11: ...F In timer mode the time will be increased or decreased by 1 hour 7 Display The display will show the following o ENERGY SAVER FAN ONLY COOL show the room temp o TIMER shown the setting timer in the f...

Page 12: ...e controller either move these appliances or consult your local dealer Replacing Batteries The remote control is powered by two AAA alkaline batteries housed in the back of the remote Do not use recha...

Page 13: ...e fan speed The auto Fan can t be set in this mode o Energy Saver In this mode air conditioner operates the Energy Saver mode The energy saver indicator will be on Press Fan Speed button can adjust th...

Page 14: ...nds Air Directional Louvers Normal Sounds When your air conditioner is operating normally you may hear sounds such as o Droplets of water hitting the condenser causing a pinging or clicking sound The...

Page 15: ...dry the filter completely before replacing to ensure maximum efficiency 4 Install the filter Cleaning the Front Panel 1 Turn off the air conditioner 2 Remove the air filter and clean it separately See...

Page 16: ...t least 3 minutes after turning the unit off before trying to restart the air conditioner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can trip...

Page 17: ...to the outside are open Close all windows and doors The Vent control is set to open on some models Push the Vent control to CLOSED for maximum cooling and or heating The temperature set point or Ther...

Page 18: ...840 1000 Plug Type LCDI 5 15P 5 15P 5 15P 5 15P Power Cord Rating amps 10 13 13 15 Power Cord Length ft 6 6 6 6 Refrigerant Charge R410a oz 14 82 16 2 20 46 24 69 Max dbA Level Indoor Outdoor 65 67 6...

Page 19: ...LABOR IS NOT COVERED 2 OUT OF CARTON ISSUES MUST BE REPORTED WITHIN ONE DAY 3 PARTS ARE COVERED FOR 1 YEAR 4 COMPRESSORS ARE COVERED FOR 1 YEAR 5 NORMAL WEAR AND TEAR IS NOT COVERED Additional claims...