- 12 -
PUMP DRAINING
P
Water can automatically be emptied into a floor drain or an appropriate drainage
facility by attaching a pump drain hose
*
to the pump drain hose outlet on the rear side
of the unit.
Installation Steps
1. Remove the continuous drain hose and the drain
hose subassembly from the unit.
2. Install the plastic cover to the continuous hose outlet
of the unit by using the two screws included.
3.
Insert the pump drain hose at least ½’’ into the pump
drain hose outlet.
4. Make sure the hose is secure so there are no leaks.
5. Lead the water hose to a floor drain or an
appropriate drainage facility.
6. Make sure there are no kinks in the hose that stop
water from flowing properly.
7. Place the end of the hose into the drain and make
sure the end of the hose is level or pointed down to
let water flow smoothly.
Do not let the hose point
up.
8. Press the Pump Button to enable the pump
operation. The Pump Light will illuminate to indicate
the pump operation is enabled. The pump will
automatically turn on when the bucket is full.
NOTE: The pump operation may be loud when it
starts working for the first 3-5 minutes.
9. Select the desired humidity setting and fan speed on
the unit to start normal operation.
10. To remove pump drain hose, press the hose in to
release then pull to remove the pump drain hose. Be
careful when removing the hose to make sure water
does not spill or drip out onto the floor.
NOTES:
o
Do not use this operation when the outdoor
temperature is less than or equal to 32°F/0°C.
Water may freeze inside the hose blocking the
flow of water and causing the unit to fail.
o
The
highest water can be pumped is 6’ (2
meters).
o
Make sure to empty the bucket once a week
while using the pump draining feature.
o
When the pump draining feature is not being
used, remove the pump drain hose from the
outlet.
o
If the Pump Light blinks, an error with the
pump has occurred. If this happens, turn off
and unplug the unit. Do the following things:
1. Make sure the pump filter is clean. To clean,
remove the bucket and take down the pump
filter.
2. Make sure the pump drain hose is properly
connected and secured to the unit.
3. Empty any water inside the bucket.
4. Reinstall the pump hose if removed and
properly place the bucket back into the unit.
5. If error repeats, call for service.
P
Pump version only
*
Pump drain hose included