background image

484 01 3600 00  

 April 2010

INSTALLATION INSTRUCTIONS

Cased N Coil, Upflow

Downflow

END4X, ENW4X

NOTE

:  Read the entire instruction manual before starting

the installation.

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Airflow

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TXV

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Inspect Equipment

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Select Installation Procedure

2

. . . . . . . . . . . . . . . . . . . . . . .

Installation of Furnace Coils

3

. . . . . . . . . . . . . . . . . . . . . . . .

Connect Refrigerant Piping

5

. . . . . . . . . . . . . . . . . . . . . . . . .

Connect Refrigerant Liquid and Suction Lines

5

. . . . . . . . .

Refrigerant Metering Device

5

. . . . . . . . . . . . . . . . . . . . . . . .

Condensate Drain Line Connection

5

. . . . . . . . . . . . . . . . . .

Waste Line Connection

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Humidifier Application

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model Number Identification

7

. . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,

maintenance, or use can cause explosion, fire, electrical

shock, or other conditions which may cause death, personal

injury or property damage. Consult a qualified installer,

service agency, or your distributor or branch for information

or assistance. The qualified installer or agency must use

factory

authorized kits or accessories when modifying this

product. Refer to the individual instructions packaged with

the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective

clothing, and work gloves. Use quenching cloth for brazing

operations. Have fire extinguisher available. Read these

instructions thoroughly and follow all warning or cautions

included in literature and attached to the unit. Consult local

building codes and the current editions of the National

Electrical Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian

Electrical Code CSA C22.1.
Recognize safety information. When you see this symbol

 on the unit and in instructions or manuals, be alert to the

potential for personal injury. Understand the signal words

DANGER

WARNING

CAUTION

, and 

NOTE

. These words

are used with the safety

alert symbol. 

DANGER

 identifies

the most serious hazards which 

will 

result in severe

personal injury or death. 

WARNING

 signifies hazards which

could 

result in personal injury or death. 

CAUTION

 is used

to identify unsafe practices which 

may 

result in minor

personal injury or product and property damage. 

NOTE

 is

used to highlight suggestions which 

will 

result in enhanced

installation, reliability, or operation.

IMPORTANT

:  Nitrogen can leak out through the hole that

the needle pierced in the plugs. This does not indicate a

leaking coil nor warrant return of the coil.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Before installing, modifying or servicing system, always

turn off main power to system. There may be more than

one disconnect switch. Lock out and tag switch with a

suitable warning label.

!

WARNING

PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal

injury.
This coil contains Nitrogen precharge of 15 PSIG.

Release of this pressure through the center of the

rubber plugs is required before removing the plugs.

CAUTION

!

ENVIRONMENTAL HAZARD

Failure to follow this caution may result in environmental

pollution.
Remove and recycle all components or materials (i.e.

oil, refrigerant, etc.) before unit final disposal.

CAUTION

!

CUT HAZARD

Failure to follow this caution may result in personal

injury.
Sheet metal parts may have sharp edges or burrs. Use

care and wear appropriate protective clothing and

gloves when handling parts.

CAUTION

!

Summary of Contents for END4X

Page 1: ...ecognize safety information When you see this symbol on the unit and in instructions or manuals be alert to the potential for personal injury Understand the signal words DANGER WARNING CAUTION and NOT...

Page 2: ...hen brazing S Place liquid filter dryer near ID unit to reduce the risk of debris clogging the valve S Make sure TXV bulb is securely fastened and wrapped in the indentation on vapor line tube END4X E...

Page 3: ...2 622 3 8 7 8 23 1 8 587 No Yes Yes END4X60 C T 24A 5 24 1 2 622 3 8 7 8 23 1 8 587 No Yes Yes END4X61 C T 24A 5 24 1 2 622 3 8 7 8 23 1 8 587 No Yes No ENW4X36 C T 17A 3 17 1 2 445 3 8 3 4 16 3 16 4...

Page 4: ...il directly on top of gas furnace with overhanging portion entirely on left side as in Figure 4 Alternative C Mark location of gas furnace flange on coil casing Remove coil from top of furnace Using t...

Page 5: ...ap TXV and nearby tubing with a heat sinking material such as a wet cloth 4 Use 1 2 psig Nitrogen purge in the suction and out the liquid line 5 Braze using a Sil Fos or Phos copper alloy Do not use s...

Page 6: ...oid drainage problems test the primary drain line by slowly pouring water into the pan Check piping for leaks and proper condensate drainage Using the secondary drain as explained in the previous note...

Page 7: ...ERANT P Piston X TXV METERING DEVICE 18 18 000 BTUH 1 tons 19 18 000 BTUH 1 tons 24 24 000 BTUH 2 tons 30 30 000 BTUH 2 tons 31 30 000 BTUH 2 tons 36 36 000 BTUH 3 tons 37 36 000 BTUH 3 tons 42 42 000...