4 Input / output synchronization
Output synchronization
An external device (switch, alarm, indicator light) can be triggered by a good read or
unsuccessful read by the MaxiScan 3100. The external device is connected to pins 7
and 8.
Output trigger
Good read
The output device is triggered when the MaxiScan 3100 performs a
good read.
No read
The output device is triggered when the MaxiScan 3100 does not perform
a good read. An input synchronization trigger is required (no read = no
read before timeout).
Hardware action
Current on
The output device operates when current flows between pins 7 and 8.
The output device stops operating when the current stops flowing. An
output trigger (good read or no read) must be activated.
Current off
The output device operates when no current flows between pins 7 and
8. The output device stops operating when the current starts to flow. An
output trigger (good read or no read) must be activated.
Software action
The MaxiScan sends a specified character following a good read or no read. This
software output can be combined with an action (current on or current off).
Summary of Contents for MaxiScan 3100
Page 1: ...P N 3 510049 01 MaxiScan3100 FixedStationScanner Installation Guide...
Page 4: ...4 MaxiScan 3100 Installation Guide...
Page 12: ...12 MaxiScan 3100 Installation Guide 1 Before you start...
Page 13: ...MaxiScan 3100 Installation Guide 13 2 Installation Mounting...
Page 16: ...16 MaxiScan 3100 Installation Guide 2 Installation...
Page 20: ...20 MaxiScan 3100 Installation Guide 3 Connections...
Page 24: ...24 MaxiScan 3100 Installation Guide 4 Input output synchronization...
Page 30: ...30 MaxiScan 3100 Installation Guide 5 Setup...
Page 34: ...34 MaxiScan 3100 Installation Guide 6 Slave mode...
Page 50: ...50 MaxiScan 3100 Installation Guide 9 Technical characteristics...