Label Design
Bar Codes (combined command)
The
BARSET
command is primarily intended for complex
2-dimensional codes (see Chapter 9.1), but can also be used to
specify more simple bar codes using a single command:
BARSET
[#<start parameter>,]"<code name>",<ratio wide bars>,<ratio
narrow bars>,<magnifi cation>,<height>
<start parameter>
optionally specifi es which parameter in the
syntax above should be the fi rst parameter
(#1–6). Thereby you may bypass some of the
initial parameters, for example code name,
ratio, and magnifi cation.
(default 1, that is, fi rst parameter = code
name)
<code name>
specifi es bar code name
(default ”INT2OF5”)
<ratio wide bars>
specifi es ratio wide/narrow bars
(default 3)
<ratio narrow bars>
specifi es ratio wide/narrow bars
(default 1)
<magnifi cation>
specifi es magnifi cation
(default 2)
<height>
specifi es height of bars in dots
(default 100)
Reset to default by:
PRINTFEED|PF