68
Chapter 8 Print Unit
8.6 Label Stop Sensor,
cont.
Replacing the Sensors, (EasyCoder 501 XP and 601 XP) cont.
To reassemble the LSS, proceed as follows:
• Thread the cables through the hole in the inner gable.
• Place the inner, lower corner of the bracket into the groove in
the carriage, almost at the innermost end.
• Tilt the bracket up at the outer end and push it inwards so the
inner notch in the bracket engages the carriage.
• Press down the outer end of the bracket, so the snap-lock
engages the outer notch.
• Press the bracket inwards as far as it goes and check that the
bracket is secured by the snap-lock.
• Connect the cable from the
lower
sensor to
P54
(marked “LSS-
BOT”) and the cable from the
upper
sensor to
P53
(marked
“LSS-TOP”) on the CPU board.
• Put back the guide plates, the electronics compartment cover,
and the power cord.
• Adjust the lateral position of the LSS.
Snap-Lock
Inner Notch
Outer Notch
Connect to P54
on CPU Board
Connect to P53