Intermec EasyCoder 501 XP & 601 XP – Service Manual
24
Chapter 3
3. Hatches and Doors
3.1 Right-Hand Door
The right-hand door gives access to:
• The media supply
• The ribbon supply
• The print mechanism
The right-hand door is fi tted to the bottom plate using two hinges
that allow the door to be rotated 180˚ downwards to a vertical posi-
tion. The door is kept shut by means of a magnetic lock. The door
can easily be removed from the hinges by pushing it forward until
the snap-lock at the rear hinge becomes disengaged.
At the inside of the door, there is a label showing how to load the
media and transfer ribbon.
Illustration shows the right-hand door of an EasyCoder 501
XP. The door of the EasyCoder 601 XP has a wider top part.
The hinges can be adjusted using two pairs of #T10 Torx screws
visible on the outside. Possibly, the other parts of the hinges, which
are fi tted to the bottom plate, may require adjustment too. Shut the
door, loosen the screws slightly and align the door with the front
moulding. Tighten the screws and check that the door runs freely
and is kept shut by the magnetic lock.
Magnetic Lock
Label
Hinges