700 Color Non-Incendive (NI) Zone 2
EMEA Mobile Computer
Important Operating Instructions
Intermec Technologies Corporation Model 700CNI
has been qualified under the ATEX Directive require-
ments of the European Union by DEMKO for use in
Zone 2 environments. UL is the ExCB responsible for
issuing the CoC under the IECEx scheme for use in the
same environment.
Hazardous Locations
This mobile computer is suitable for use in the follow-
ing hazardous locations:
• Zone 2, II 3 G EEx nL IIC T6 Operating Tempera-
ture Range -10°C and +40°C (+14°F and +104°F).
• Zone 2, Ex nL IIC T6 from -10°C and +40°C
(+14°F and +104°F).
Warnings and Cautions
All warnings and cautions herein must be observed for
the safety of the operator and others in potentially haz-
ardous Zone 2 locations:
• The 700CNI must only be used when the ambient
temperature is between -10°C and +40°C (+14°F
and +104°F).
• Use battery pack P/N: 318-013-003 or 318-013-
004.
• The batteries may NOT be changed or charged in
potentially hazardous locations.
• The 700CNI may NOT be connected to any of its
available accessories while in potentially hazardous
locations. This includes anything that uses the com-
munications docking connector, headset, or micro-
phone jacks.
Note
: Use of the 700CNI outdoors requires
using the Intermec accessory cover (P/N:
815-052-001).