Intermatic WL100HPS Installation Instructions Download Page 1

ELECTRICAL REQUIREMENTS

A  qualified  electrician  should  complete  all  required  wiring.  Models  WL100HPS  &  WL100MH  will  accept  120,  208,  240 
or  277  Volts  AC.  Models  WL100HPST  &  WL100MHT  will  accept  120,  277  or  347  Volts  AC.  Fixtures  must  be  properly 
grounded  for  safety.  A  mounting  suitable  for  outdoor  use  and  rated  for  wet  locations  is  required.  Follow  all  applicable 
electrical codes and regulations.

7.48in.

(190m m )

8.86in.

(225m m )

8.46in.

(215m m )

Mounting

Plate

Locknut Inside Fixture

HID Wall Pack - WL Series

INSTALLATION INSTRUCTIONS

Models: WL100HPS, WL100HPST, 

 WL100MH, WL100MHT

FOR OUTDOOR USE ONLY

NOT FOR USE IN HAZARDOUS 

ATMOSPHERES

IMPORTANT: Read instruction sheet 

carefully before installing fixture. Retain 

instructions for future reference.

Please see below for list of warnings.

 

 

WARNING 

  Electric shock hazard

Disconnect power at circuit breaker or fuse box before 
installing or servicing light. 

 

 

WARNING 

  Fire hazard

USE MIN 60°C SUPPLY CONDUCTORS. CONNECT TO 
SUPPLY IN EXTERNAL JUNCTION BOX ONLY. 
Lamp and housing become very hot during use. Ensure free 
air circulation around unit to dissipate heat. Avoid enclosed 
locations and locations where flammable debris (leaves, cut 
grass, etc.) might collect. Avoid locations where humans or 
animals might accidentally touch fixture.

 

 

WARNING 

  Explosion hazard

Never operate light without securing the lens door. When 
light is operating, the gas in the lamp inner arc tube is at 
high pressure. Never operate light if the fixture lens or outer 
glass envelope of the lamp is broken or missing.

 

 

WARNING 

  Explosion hazard

Wear safety glasses and gloves when handling lamp, High 
Pressure Sodium outer envelope is under vacuum and 
could implode. Metal Halide outer envelope is pressurized 
and could explode if broken.

 

 

WARNING 

  UV hazard 

(Metal Halide Lamps Only)

The type of lamp used in this fixture can cause serious 
skin burn and eye inflammation from short wave ultra 
violet radiation if outer envelope of the lamp is broken or 
punctured, and the arc tube continues to operate. Do not 
use where people will remain for more than a few minutes. 
Certain types of lamps that will automatically extinguish 
when the outer envelope is broken or punctured are 
commercially available.

 

 

WARNING

            Figure 1
Mount Fixture horizontal

Screws

Lens 

Cover

Screws

MOUNTING & WIRING

Loosen  (4)  screws,  open,  and  remove  fixture  lens  cover. 
Set  lens  cover  aside  to  prevent  damage  while  installing. 
(See Figure 1)
Loosen (2) screws and remove reflector.
Remove locknut from mounting plate threaded nipple inside 
fixture. Separate mounting plate from fixture.
Apply provided gasket to back of mounting plate for sealing 
against junction box.
Identify supply voltage.

6.  Select  appropriate  fixture  wire  to  match  incoming  voltage. 

Models WL100HPS & WL100MH are shipped with 277 V wire 
ready  for  connection.  Models  WL100HPST  &  WL100MHT 
are shipped with 347 V wire ready for connection. If supply 
voltage is lower, cap wire marked 277 V (or 347 V for tri-tap 
models) with appropriate twist on wire connector and strip 
fixture  wire  marked  with  matching  voltage.  (See  Figure  2 
through Figure 5)

1.

2.
3.

4.

5.

Lamp Types: 

High Pressure Sodium 100 Watt 
High Pressure Sodium 100 Watt with Tri-Tap
Metal Halide 100 Watt
Metal Halide 100 Watt with Tri-Tap