background image

158TS11854

Note:

1. ALL MARKINGS TO BE PER

INTERMATIC APPROVED

ARTWORK.

DR:   SRB 8/24/2004

ITEM

PART NUMBER

DESCRIPTION

QTY

ORIG:

INTERMATIC INCORPORATED

CHKD: GLM  8/24/2004   

SCALE:  FULL

NAME:          

INST SHT - DOOR, T8805P101C - ENG

APPROVED

MATL:     

WHITE PRESSURE SENSITIVE STOCK

1       RELEASED TO ELEC.  DATA

T8805P101C

GLM  8/24/2004

FINISH

:        

BLACK PRINTING INK

LET

REVISION

DATE/BY

MODEL

SUPERSEDES

HEAT TREAT

+1/32

3

7/8

TOOL TOL: 

BOXED TOLERANCES ARE FOR LIFE-OF-TOOL DEVIATION ONLY.

DO NOT USE FOR RE-TOOLING.

DIM  TOL. :  

DECIMALS (UNLESS OTHERWISE SPECIFIED) - TWO PLACE (.00) + .015 - THREE PLACE (.000)+ .005

 30 MINUTES - ALL DIMENSIONS MUST BE MET BEFORE PLATING.

R (OPTIONAL)

D17

+1/32

6

3/4

SEE B/M FOR ALL PART NUMBERS & QUANTITIES

MODEL: T8805P101C

PROGRAM TIME SWITCH WITH 
14-DAY "SKIPPER

®

" WHEEL

FOR UP TO 60 OPERATIONS PER DAY
SWITCH RATING: SINGLE POLE SINGLE THROW
15 AMP., 1/2 H.P.125 VOLTS A.C.

CLOCK MOTOR:  125  VOLTS - 60 HZ.

PROGRAMMING INSTRUCTIONS:

1. 

TO SET FIRST ZONE: For watering, push gold pin into slot on yellow 

dial at desired ON time. For each 12 minutes of additional watering
add one pin WITHOUT skipping a slot.

2. 

TO  CHANGE ZONES: Leave one blank slot on yellow dial after ON

line (gold pin), and valve will automatically advance to next zone.

3. 

TO SET ADDITIONAL ZONES: Repeat steps 1 and 2. REMEMBER

to leave blank space between zones

4. 

TO SET TIME OF DAY: Turn yellow dial CLOCKWISE, until correct

line is at end of silver time pointer. Do NOT turn silver pointer.

5. 

TO SKIP DAYS: Turn black skipper wheel COUNTER-CLOCKWISE

until todays day is in front of "14" arrow. Press pins DOWN on days
of NO watering. The skipper wheel must have all pins UP for daily
watering.

6. 

PUT SELECTOR SWITCH IN AUTO: This switch can be used to turn

the system ON or OFF for manual operation without affecting the set
program.

IMPORTANT NOTICE: Use the one silver pin that is located at Midnight
on the yellow dial, it advances the skipper wheel automatically. Do 

NOT

use multiple silver pins.

Follow The National Electrical Code and local code requirements when
installing this time switch.

CAUTION: Always disconnect power at main panel before servicing 
this Switch or the equipment it controls.

INTERMATIC INCORPORATED

SPRING GROVE, ILLINOIS 60081-9698

158TS11854                                                                                      

TIME
POINTER

DIAL

SKIPPER

AUTO

TIME

DAY

SELECTOR
SWITCH

FIGURE 1

WIRING DIAGRAM

GROUND TO

120 VOLT
POWER
SUPPLY

NOT FOR DIRECT PUMP CONTROL

TO

SOLENOID

COMMON

CLOCK

NEUTRAL
(WHITE)

LINE
(BLACK)

LR3730

   

 

 

                                     

 

 

 