background image

RC SERIES

REMOTE CONTROLS

INSTALLATION

OPERATION &

SERVICE MANUAL

SINGLE CHANNEL RADIO RECEIVER with RELAY

Model: RC613R  

For indoor and outdoor use, suitable for Pool/Spa equipment control

ElEctrical rating: 30 amp resistive-120V or 240Vac, 12.5 amp (1500 Watt)

   

 

 

 

tungsten - 120Vac, 1.5 H.P. - 120Vac, 3.0 H.P. - 240Vac DPSt

tHiS DEVicE cOMPliES WitH Fcc rUlES Part 15. Operation of this device is subject to the following two conditions: 

1. This device may not cause harmful interference. 2. This device must accept any interference that may be received, 

including interference that may cause undesired operation. FCC rules prohibit adjustments to or modification of receiver and 

transmitter circuitry except for replacing the transmitter battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.

this Heavy Duty Modular radio receiver is one half of a two part remote 

control system. It operates as an ordinary ON/OFF switch, but it also responds 

to the signals of a hand-held transmitter - the other half of the system. The Module 

is designed for indoor and outdoor use, works on either 120 or 240 volts and can 

handle a variety of switching applications, typical around the house or farm. 

By the push of a button on the face of the transmitter, the user is able to turn ON/

OFF the connected load (lights, pump, etc.) from any remote location*, 

inside or outside of the house, safely and conveniently. In addition, a single 

transmitter can operate up to three receivers and is able to “teach” each Module 

a different code. (Transmitters are sold separately.)

the Module comes with its own manual ON/OFF button and it is intended to be 

used as a three-way switch, one at the location and the other being the transmitter. 

The connected load will respond to either of the two controls or may be turned 

ON using the hand-held transmitter and turned OFF by pushing the red button 

on the face of the receiver or vice versa.

the Module consists of a Receiver Unit and a Relay Box permanently connected 

together with a seal between them. The Receiver Unit is welded and has no user 

serviceable parts inside. The Relay Box has two compartments, one for the 120 

volt coil, double pole relay and the other for making the field connections.

Operation: Upon receiving a valid signal from a designated transmitter, 

the Receiver Unit will reverse the state of the relay contacts, that is, it will 

turn ON or OFF the connected load. In order to prevent bodily injury and/or 

equipment damage after a power failure, the contacts of the relay remain open 

until the button on the face of the Receiver Unit or on the transmitter is pushed.

*  The range is 200 feet but depends on many factors like the age of the battery, 

  proximity of large metal objects, the location of the receiver and environmental 

  conditions at the time of transmission.

1

IMPORTANT SAFETY INSTRUCTIONS

1.  This Control must be installed by a qualified electrician, according to National Electric Code (Including article 680) or Canadian Electric

  Code (Including Section 68) and Local Electrical Codes. 

2.  USE COPPER CONDUCTORS ONLY. If applicable, install this Control not less than 5 feet (3 meters for Canadian instructions) 

  from inside edge of pool or spa.

3.  Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.

4.  For grounding of the installation, refer to article 250 and 680 of the National Electrical Code. (For Canadian Installations:

  Section 10 and 68 of the Canadian Electric Code)

5.  This Control should not operate any equipment which would cause bodily injury or property damage should it be activated unexpectedly.

6.  Always disconnect electricity at main panel before servicing this Control or the equipment(s) connected to it. 

  THIS CONTROL IS NOT TO BE USED AS A POWER DISCONNECT.

READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL

GENERAL INFORMATION

Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material 
contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.

INTERMATIC INCORPORATED, SPRING GROVE, IL 60081

158RC10000 

 

 

 

 

 

 

 

 

 

  

   

4

WARRANTY

 

If within one (1) year from the date of installation, this product fails due to a defect in material or workmanship, Intermatic Incorporated 

will repair or replace it free of charge.

 

The warranty does not cover labor for removal or reinstallation and does not apply to: (a) damage caused by accident, abuse, mishandling, 

or dropping; (b) a unit which has been subject to unauthorized repair; (c) units not used in accordance with directions; (d) damages exceeding 

the cost of the product. Some states do not allow a limitation of damages so the foregoing warranty may not apply to you. This warranty gives 

you specific legal rights and you may also have other rights which vary from state to state.

 

This warranty service is available, if the defective product or its defective component is returned with proof of purchase and date of     

installation, either (a) to the dealer from whom the unit was purchased or (b) by shipping prepaid to the Intermatic Service Center, Intermatic 

Incorporated, Intermatic Plaza, Spring Grove IL 60081-9698

LIST OF AVAILABLE MODELS AND COMPONENTS

Model 

Description 

Specifications

RC613 

Single Channel Receiver 

10 Amp Resistive, 5 Amp (600 Watt) Tungsten,

 

3-way Switching Module 

1/3 HP Motor Load - 120 Volt.

RC613R 

Heavy-Duty Receiver 

30 Amp Resistive - 120/240 Volt, 12.5 Amp (1500 Watt) 

 

and Relay Assembly 

Tungsten - 120 Volt, 1.5 HP - 120 Volt, 3 HP - 240 Volt

 

 

Double Pole Single Throw Contacts.

RC615 

Single Channel Receiver 

10 Amp Resistive, 5 Amp (600 Watt) Tungsten

 

Timer Override Module 

1/3 HP Motor Load - 120 Volt.

RC939 

3 Channel Transmitter 

Operates on 9 Volt Battery

P1103M 

24 hr. Timer 

Mechanical Timer Mechanism -

 

Mechanism Only 

replaces Intermatic T100 Series timers and compatible

 

 

with RC615 Receiver. Same rating as RC613R

TROUBLESHOOTING

Symptom 

Possible cause(s) 

corrective action

No response to transmitter  

No power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Turn ON power at main panel

signal at anytime 

Loose connection(s) at receiver and/or load. . . . . . . . . . .Check connections

 

Transmitter battery dead . . . . . . . . . . . . . . . . . . . . . . . . . .Replace battery

 

Receiver and transmitter are on two different codes . . . .Change code settings (see page 3)

 

Faulty transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Check battery connections, replace transmitter

 

Faulty receiver  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace Receiver Module

No response to transmitter 

Weak Battery  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace battery

signal some of the time 

Appliance with brush type motor is in use. . . . . . . . . . . .Relocate appliance and/or connect to another circuit

 

Other radio transmitter (police, etc.) 

 

is operating nearby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Change master code of transmitter (See page 3)

 

Receiver is at edge of range . . . . . . . . . . . . . . . . . . . . . . .Mount Receiver closer or higher

Insufficient Range 

Weak battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace battery

 

Antenna too close to ground. . . . . . . . . . . . . . . . . . . . . . .Relocate Receiver Module

 

Transmitter is held too close to ground . . . . . . . . . . . . . .Hold transmitter at least 3 ft. above ground

 

Weak signal due to obstruction  . . . . . . . . . . . . . . . . . . . .Remove/relocate Receiver Module

Nuisance operation 

Other radio transmitter operating nearby . . . . . . . . . . . . .Change master code of transmitter (See page 3)

 

Fluctuating supply voltage due to surge, etc. . . . . . . . . . .If frequent - install surge suppressor

 

Faulty receiver  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace receiver module