background image

POOL/SPA CONTROL ACCESSORIES

INSTALLATION

& OPERATING

INSTRUCTIONS

Model:  RC4G Air Button

for Gunite / In-Wall Applications

This Air Button is especially suited for gunite/concrete 
type construction and it is designed to slip-fit inside of 
a schedule 40 PVC conduit. Because of its low profile, 
it is the perfect choice for both the vertical and the 
horizontal mounting arrangements. It will operate any 
Intermatic relay type Air Control up to 100 feet away.

1. Make sure the distance between the Air Control and 
  Air Button is not over 100 feet.
2. Install PVC conduit between the Air Control and Air
  Button, using sweep elbows or forming large radius 
  curves with heat gun.
3.  At pool/spa side, make sure the conduit is the 1 inch 

I.D., either rigid or the flexible type, and extends well 
beyond the intended finished surface.

4.  When the pool/spa deck work is complete, cut 

conduit flush with finished surface. Try Air Button for 
fit. Due to irregularities and variations in conduit I.D. 
some sanding of I.D. may be required.

5.  Pull 1/8 inch I.D. vinyl tubing between Air Control 

and Air Button, allowing 6 to 10 extra inches at both 
ends. Make sure the tubing is especially formulated 
for such an application (we recommend using tubing 
supplied by 

Intermatic

), free of kinks, splices and 

protected from chemicals and rough edges. 

Do 

not allow water or other contaminants to enter 
tubing.

6.  Slide retaining nut over tube and firmly 

press tube over air buttons connecting 
nipple. Hand tighten nut over the threaded 
portion of Air Button (see illustration 
above).

7.  Push excess tubing back into conduit 

and press Air Button into conduit. Apply 
small amount of silicone sealer around the 
flange of Air Button and snap bezel over 
flange. 

The use of permanent glue is not 

recommended.

1

Instructions

Troubleshooting

 

SYMPTOM 

CAUSE(S) 

CORRECTIVE ACTION

Air Button would not operate 

1.  Loose air tube connection. 

Check connections.

equipment. (See also “Useful 

2.  Water in air tube. 

Blow out tube.

Information” on back).

 

3.  Air Control is too far from 

Change Air Button to larger size.

 

  Air Button.

 

4.  Defective Air Button. 

Change out Air Button.

 

5.  Defective control and/or  

Check out installation.

 

 equipment.

 

6.  No power to control. 

Turn breaker ON.

 
 Bezel

Reviews: