background image

FL300MSW Instruction Manual

Two Head Flood Light with Motion Sensor

                      

                

WARNING:  Risk of Electric Shock

• If you are not experienced with proper wiring practices, consult a qualified electrician.
• All wiring must comply with local and national electrical codes.
• Before wiring ensure power is turned off at the fuse box or circuit breaker panel.

Technical Specifications

Housing Size (H x W x D) 

3 1/2” X 2 4/5” X 4 1/2”

Supply Voltage 

120 V / 60Hz

Switching Capacity 

Maximum 300 Watts

Detection Angle of Sensor 

140˚ Horizontal / Plane A (10 zones)

Sneak-by Guard 

90˚ Horizontal / Plane B (6 zones)

 

8˚ Vertical

Swiveling range of sensor 

130˚  Horizontal, 65˚ Vertical

Range over which detection is  

270˚ Horizontal

adjustable
“On” time: 

10 seconds to 15 Minutes, adjustable

Sensor Range 

Minimum 40’ in front, 23 Feet at sides (based on 10’ 

 

mounting height)

Type of enclosure 

Rain tight

Lamps (not included) 

Maximum 150 Watt Par 38 or Quartz flood lamps

 

PL fluorescent flood with low temp start

Installation 

Wall mount or soffit/eave mount applications