background image

MOUNTING & WIRING

Screw  the  threaded  mounting  arm  of  the  fixture  into 
1/2” NPS  mounting  hole  on  mounting  device.  Tighten 
locknut to secure fixture. (See Figure 1)
Using  provided  twist  on  or  other  approved  connectors, 
connect  the  fixture  wires  to  the  supply  wires  as  follows: 
(See Figure 2 or Figure 3)

Identify supply voltage.

Open lens door and remove reflector.
Select  appropriate  fixture  wire  to  match  incoming 

voltage. Models FL050MH, FL070MH & FL100MH are 
shipped with 277 V wire ready for connection. Models 
FL050MHT,  FL070MHT  &  FL100MHT  are  shipped 
with 347 V wire ready for connection. If supply voltage 
is lower, cap wire marked 277 V (or 347 V for tri-tap 
models) with appropriate twist on wire connector and 
strip fixture wire marked with matching voltage.

Confirm unused voltage fixture wires are appropriately 

capped within fixture body.

1.

2.

a.

b.
c.

d.

)

8.07in.

(205mm)

9.02in.

(229mm)

7.44in.

(189mm)

6.81in.

(173mm)

4.65in.

(118mm

5.95in.

(151mm)

Figure 1

Install with lamp horizontal

Clips

Lampholder

Lens Door

Hinge

Reflector

Mounting Arm Bolt

Locknut

FOR OUTDOOR USE ONLY

NOT FOR USE IN HAZARDOUS 

ATMOSPHERES

IMPORTANT: Read instruction sheet 

carefully before installing fixture. Retain 

instructions for future reference.

HID Flood Light - FL Series

INSTALLATION INSTRUCTIONS

Models: FL050MH, FL070MH, FL100MH,

FL050MHT, FL070MHT & FL100MHT

ELECTRICAL REQUIREMENTS

A qualified electrician should complete all required wiring. Models FL050MH, FL070MH & FL100MH will accept 120, 208, 
240 or 277 Volts AC. Models FL050MHT, FL070MHT & FL100MHT will accept 120, 277 or 347 Volts AC. Fixtures must 
be properly grounded for safety. A mounting suitable for outdoor use and rated for wet locations is required. Follow all 
applicable electrical codes and regulations.

Please see below for list of warnings.

 

 

WARNING 

  Electric shock hazard

Disconnect power at circuit breaker or fuse box before 
installing or servicing light. 

 

 

WARNING 

  Fire hazard

USE MIN 60°C SUPPLY CONDUCTORS. CONNECT TO 
SUPPLY IN EXTERNAL JUNCTION BOX ONLY. 
Lamp and housing become very hot during use. Ensure free 
air circulation around unit to dissipate heat. Avoid enclosed 
locations and locations where flammable debris (leaves, cut 
grass, etc.) might collect. Avoid locations where humans or 
animals might accidentally touch fixture.

 

 

WARNING 

  Explosion hazard

Never operate light without securing the lens door. When 
light is operating, the gas in the lamp inner arc tube is at 
high pressure. Never operate light if the fixture lens or outer 
glass envelope of the lamp is broken or missing.

 

 

WARNING 

  Explosion hazard

Wear safety glasses and gloves when handling lamp. Metal 
Halide outer envelope is pressurized and could explode if 
broken.

 

 

WARNING 

  UV hazard 

(Metal Halide Lamps Only)

The type of lamp used in this fixture can cause serious 
skin burn and eye inflammation from short wave ultra 
violet radiation if outer envelope of the lamp is broken or 
punctured, and the arc tube continues to operate. Do not 
use where people will remain for more than a few minutes. 
Certain types of lamps that will automatically extinguish 
when the outer envelope is broken or punctured are 
commercially available.

 

 

WARNING

Lamp Types: 

Metal Halide 50 Watt, 70 Watt & 100 Watt
Metal Halide 50 Watt, 70 Watt & 100 Watt with Tri-Tap