Specifications

CLOCK VOLTAGE: 120 V.A.C., 60 Hz.
POWER CONSUMPTION: 3.0 Watts Max. (ET101C) &

(ET105C)

5.0 Watts Max. (ET103C)

CONTACT CONFIGURATION:  SPST model  ET101C
DPST model  ET103C, & SPDT model ET105C.
SWITCH RATING: (Per Pole for ET103C)

30 Amps Inductive/Resistive, 24/120/240 V.A.C., 60 Hz.

20 Amps Resistive - 28 V.D.C.,

1 H.P. 120 V.A.C., 60 Hz.

2 H.P. 240 V.A.C., 60 Hz.

5 Amps Tungsten, 120/240 V.A.C., 60 Hz.

20 Amps Ballast 277 V.A.C., 60 Hz.

SWITCH RATINGS: ET105C
N.O.             N.C. CONTACT
20 AMP

10 AMP

Resistive and          28 VDC. 
General Purpose    120-240 VAC

1 H.P.           1/4 H.P.          MOTOR                 120 V.A.C.
2 H.P.           1/2 H.P.          MOTOR                  240 V.A.C.
5 Amp               -                TUNGSTEN           120-240 V.A.C.
20 Amp         3 Amp            BALLAST

120-277 V.A.C.

SET POINTS (EVENTS): 8 total (4 ON/4 OFF).
BATTERY POWERED CLOCK OPERATION: 3 Years minimum
(AA industrial grade alkaline supplied with time switch)
MIN. “ON” or “OFF” TIME: 1 minute.
MAX. “ON” or “OFF” TIME: 23 hours 59 minutes.
SHIPPING WEIGHT: 2,5 Lbs. (1.1 Kg)
CASE: Drawn steel; 7-3/4” (19.7 cm) high, 5” (12.7 cm)
wide, 3” (7.6 cm) deep; gray finish w/lockable spring hasp.
KNOCKOUTS: Combination 1/2 - 3/4” (one on back and 
each side, two on bottom).
WIRE SIZE: AWG #10 through #18.

General Safety Information

WARNING: Disconnect all power before installing or
servicing this time switch or its connected loads.
1. Follow all local electrical and safety codes, National

Electric Code (NEC), as well as Occupational Safety and 
Health Act (OSHA).

2. If the power disconnect point is out of sight, lock it in the “OFF” 

position and tag it to prevent unexpected application of power.

3. This time switch case must be grounded.
4. Do not exceed the maximum current carrying capacity of this 

time switch.

5. Always replace the plastic  insulator covering the terminal 

before turning power “ON”.

AM        ON

5:20

Description

The Intermatic Electronic 24 Hour Time Switch automatically
switches loads according to a preset daily schedule.
This time switch is designed to directly switch loads up to 30 amps
and to switch resistive or inductive loads up to the time switch rat-
ing. For use as a control timer in applications requiring 24 hour
load control such as lighting, heating, air conditioning systems,
pumps, etcetera. Up to eight set points or events (4 ON/4 OFF) can
be preset. this schedule will repeat on a daily basis. The program
can be overridden by using the MANUAL position.

    

Summary of Contents for ET101C

Page 1: ...9 minutes SHIPPING WEIGHT 2 5 Lbs 1 1 Kg CASE Drawn steel 7 3 4 19 7 cm high 5 12 7 cm wide 3 7 6 cm deep gray finish w lockable spring hasp KNOCKOUTS Combination 1 2 3 4 one on back and each side two on bottom WIRE SIZE AWG 10 through 18 General Safety Information WARNING Disconnect all power before installing or servicing this time switch or its connected loads 1 Follow all local electrical and ...

Page 2: ...e supply and load wires by removing 1 2 inch of insulation DO NOT USE ALUMINUM WIRE See figure 3 4 or 5 Insert the wire ends under the proper terminal plates and tighten the screws firmly Use AWG 10 through 18 Connect ground wire to grounding terminal at bottom of case 6 Replace the plastic insulator 7 Be sure that the battery is functioning properly this can be checked by making sure the display ...

Page 3: ...ode causes the event time displayed to be removed from the program The display will show 0 00 and the Event 1 through 8 To Operate Timer After programming is complete move the selector switches to the RUN and AUTO positions The time switch will follow the scheduled program but will not immediately catch up to the presently programmed load condition the time switch will catch up at the next schedul...

Page 4: ... terminals 1 and 2 This allows the timer to switch various loads LIMITED ONE YEAR WARRANTY If within one 1 year from date of purchase this product fails due to a defect in material or workmanship Intermatic Incorporated will repair or replace at its sole option the unit free of charge This warranty applies only to the original purchaser and is not transferable The warranty does not apply to a dama...

Reviews: