Product Summary 

 
The UM-W7 allows the addition of up to 192 wireless devices to your UltraSync 
Modular Hub system. These include wireless reed switches, wireless motion 
sensors, and keyfobs. 
 
The receiver is in a self-contained plastic housing and connects to your UltraSync 
Modular Hub via the standard 4 wire BUS. 
 
Additional features include: 2 hardwired zone inputs, 1 relay output, front and rear 
tamper. 

 

Current Limit Warning 

 
Check the current requirements of your load before connecting!  
 
There is no overcurrent protection on the relays when providing bus ground or bus 
voltage (jumper between NEG and C, or C and AUXIN). You must ensure your load 
does not exceed the recommended limits below. Exceeding limits can damage the 
module and pose an electrical hazard. 
 
The UltraSync Modular Hub CPU does have overcurrent protection on the bus and 
may disconnect the bus to provide temporary protection. If enabled, your panel will 
report "Overcurrent Fault" or "Expander Overcurrent". Repeated overcurrent 
conditions can result in permanent damage to the panel or connected devices.

 

 

Installation Guidelines 

 
When installing the receiver: 
 

 

Leave 

≈ 4” (10cm) clear around all sides of the module for better signal 

reception. 

 

Avoid installing on or near metal surfaces such as filing cabinets and metal roller 
shutters. 

 

Avoid installing on or near electrical devices such as refrigerators, vacuum 
cleaners, air conditioners, computers, washing machines, and motors. 

 

Avoid areas that are damp and wet such as inside bathrooms. 

 

Installing the Receiver 

 

1.  Remove the front plastic housing by loosening the bottom screw. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
2.  Carefully remove the circuit board from the rear plastic housing by squeezing on 

the side tabs. Take care to put aside the two rubber tamper switches. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

3.  Feed the BUS cable through one of the cable holes. 

4.  Screw the rear plastic housing to a fixed surface. Higher positions generally 

provide better signal reception. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

5.  Re-install the rear rubber tamper button if it was removed. 

6.  Re-install the circuit board in to the plastic housing taking care to position the 

antennas in the up position. 

7.  Connect the buss cable to J1 on the UM-W7. Refer to control panel installation 

manual for cable requirements. 

8.  If required, connect zone cabling and output cabling to J3 and J6 on the UM-W7. 

Refer to “Note on Relay Modes” below. 

9.  Set J2 TERM link if required. Refer to control panel installation manual. 

10.  Turn on the power to the control panel and wait for panel to complete 

initialization. 

11.  The lights on the receiver should light as indicated: 

 
 
 

 

 

English Installation Sheet 

UltraSync  Modular Hub 
Wireless Expansion Module 
Installation Sheet 

UM-W7 

TM 

PLEASE READ THE ULTRASYNC MODULAR HUB REFERENCE GUIDE BEFORE USING THIS 
PRODUCT WHICH INCLUDES IMPORTANT SAFETY AND LEGAL INFORMATION INCLUDING 
WARNINGS, WARRANTY DISCLAIMERS, AND LIMITATIONS OF LIABILITY, AND COMPLETE 
INSTRUCTIONS ON HOW TO ENROLL AND CONFIGURE EXPANSION MODULES. THE REFERENCE 
GUIDE IS AVAILABLE AT: http://www.interlogix.com/intrusion/product/ultrasync-modular-hub 
 
S'IL VOUS PLAÎT LIRE LE GUIDE DE REFERENCE POUR LE HUB UltraSync MODULAIRE AVANT 
D'UTILISER CE PRODUIT QUI COMPREND LA SÉCURITÉ IMPORTANT ET JURIDIQUES 
INFORMATIONS, Y COMPRIS LES AVERTISSEMENTS, GARANTIE EXCLUSIONS, ET LIMITATIONS DE 
RESPONSABILITÉ ET INSTRUCTIONS COMPLETES SUR COMMENT ENROLLER ET CONFIGURER 
LES MODULES D’EXPANSION. LE GUIDE DE RÉFÉRENCE 
EST DISPONIBLE AU: http://www.interlogix.com/intrusion/product/ultrasync-modular-hub. 

Reviews: