  TX-E251 Long-Range Extended Battery Life DWS

PLEASE SEE REVERSE SIDE FOR IMPORTANT PRODUCT 
WARNINGS AND DISCLAIMER INFORMATION. 

 

Description 

 

The TX-E251 Long-Range Extended Battery Life DWS is a sensor intended for 
installation on doors, windows, and other objects that open and close. The 
sensor transmits signals to the control panel when a magnet mounted near the 
sensor is moved away from or closer to the sensor. The TX-E251 features a 
high capacity CR2 lithium battery for extended battery life, and maximum 
performance output power for long range applications. The sensor features two 
separate zones: zone 1 can be used for either of the two reed switches, and 
zone 2 can be used as an external contact option. The sensor is also equipped 
with a cover tamper switch for additional security.  

Figure 1: TX-E251 

 

 
 
 
 
 
 
 
 
 
 

Reed Switch Enrolling 

 

To enroll the TX-E251 into the panel for utilization of the 

transmitter’s reed-

switches, follow these steps: 

1) 

Place the panel into program mode, then go to Learn Sensors menu. 
Refer to your specific alarm panel manual for details on these 
menus.   

2) 

Remove the battery pull tab to auto-enroll. Then select the 
appropriate sensor group and number.  

3) 

If the panel does not respond upon removing the battery pull tab, 
disengage the case cover from the back housing by sliding, then 
remove and replace the battery until the panel responds. 

 

External Contact Enrolling  

 

To enroll the TX-

E251 into the panel for utilization of the transmitter’s external 

contact, follow these steps: 

1) 

Remove the battery OR make sure the pull tab is still in place 
between the positive battery terminal and the battery contact. 

2) 

Connect the external contact in the restored state (4.7K for normally 
closed, or open circuit for normally open). 

3) 

Install the battery OR remove the pull tab, and install and lock the top 
cover on to the sensor. 

4) 

Place the panel into program mode, then go to Learn Sensors menu. 
Refer to your specific alarm panel manual for details on these 
menus.   

5) 

To auto

–enroll the external contact into the panel, change the state 

of the external contact to the faulted state (open circuit for normally 
closed contact or 4.7K for a normally open contact). 

6) 

If the panel does not respond, then repeat steps 1 through 5. 

 

External Contact Wiring 

Use the following specifications for the external contact: 

• 

Maximum wire length: 26 ft. (8 m). 

• 

Wire: Stranded, 22-gauge (0.7112 mm). 

• 

Switches: Hermetically sealed external switches (sealed reed 
switches) that supply a minimum 250 ms open or close on alarm. 

Note:

 Do not connect more than five external contacts to a door/window 

sensor. 

Caution

: You must install the provided EOL resistor at the external detection 

device for proper supervision.  

You can wire the sensor terminal blocks with leads from an external contact 
(Figure 2). The door/window sensor provides alarm and tamper indication. Wire 
the external contact with one end-of-line (EOL) resistor in series with the 
external contact. 

 

This gives the following readings for each configuration: 

Normally closed:

  

• 

Zero ohm/short = Tamper  

• 

4.7 Kohm = Normal  

• 

Open = Alarm 

Normally open:

  

• 

Zero ohm/short = Tamper  

• 

4.7 Kohm = Alarm 

• 

Open = Normal 

 

Figure 2: External Contact Wiring 

 

 

 

Mounting 

Included with this device is double sided tape for the transmitter and magnet, 
as well as screws if a more secure method of mounting is preferred. Choose a 
suitable location for the sensor by following the procedure in the section 
“Testing the Sensor” ensuring desired signal strength is achieved. Note that it is 
recommended the transmitter be installed on the stationary or non-moving part 
of the installation (frame) and the magnet installed on the moving object (door). 
Where possible, install sensors within 100 ft. (30 m) of the panel. While a 
transmitter may have an open-air range of 500 ft. (150 m) or more, the 
environment at the installation site may have a significant effect on operational 
range. Changing a sensor location may improve wireless communication. 

For reliable bonding with the provided double sided tape, ensure the surface is 
clean and dry. Apply the tape to the backside of the sensor, and then to the 

 

Reviews: